Вимірювання активної потужності реактивного навантаження в широкому діапазоні частот

Abstract

Problem of developing a metrological instrument for measuring active power in the frequency range from 0.01 to 10 MHz is considered in the article. Construct- ing of such an instrument must meet a high requirement of channels phase charac- teristics at a low power factor at measuring active power against the background of large reactive one. In today's electric power converters, the main losses that determine the effi- ciency factor are shifted from semiconductor keys to reactive elements. In order to optimally design such reactive elements, it is necessary to be able to analyze the components of the loss [1]. Such an instrument will measure the loss power (active power) in a variety of reactive elements, for example, chokes used in pulsed ener- gy converters [2]. In currently available power analyzers and wattmeter, there are significant er- rors in the frequency range above 1 MHz, which makes it difficult to meet the above objectives [3]. An example of the harmonic signal components effect and errors analysis caused by the measurement channels phase shifts in the wattmeter is described in the article. At high frequencies, the wattmeter channels become very sensitive to phase er- rors. It is necessary to minimize links that cause phase shifts. In this connection, it is important to construct correctly wattmeter input links and to make such a trans- formation, which will provide operations with signal rms modules without taking into account phase shifts. In order to solve this problem, it is advisable to use a broadband wattmeter of transient power with the correction of the error from its own consumption, described in [6]-[8], to minimize losses and optimize the sys- tem. The wattmeter of this design gives the exact value of the measured power on the load, regardless the actual consumption of the input device. The value of the input device elements can be optimized by the criterion of maximum broadband, since the error from its own consumption is taken into account. In the scheme one low-level shunt is used. It reduces wattmeter cost and also reduces voltage conver- sion channel additive errors. The wattmeter basic error is the error of the low-ohm shunt. To extend the fre- quency range, it is advisable to use coaxial or tri-axial shunts. It is expedient to use thermocouples measuring device to determine precisely the active component in a wide frequency range.

Authors and Affiliations

Юліан Михайлович Туз, Антон Валерійович Вдовиченко Вдовиченко

Keywords

Related Articles

Вимірювання активної потужності реактивного навантаження в широкому діапазоні частот

Problem of developing a metrological instrument for measuring active power in the frequency range from 0.01 to 10 MHz is considered in the article. Construct- ing of such an instrument must meet a high requirement of c...

The stress-strain state determination in pipelines welded joints

Stress-strain state in welded joints of pipelines was determined. An axisymmetric calculation model was used,n the study of stress concentration in a weld. The dependences of stress and strain distribution in the weld zo...

Aerodynamic characteristics of telescopic wing

In the last decade folding tube launch of UAV became common, for which telescopic wings are reasonable. Nowadays, telescopic wing aerodynamic characteristics are researched much less than constant geometry wing. In prese...

Justification of the method of heat utilization of the air condition- ing system for the heat pump heating system

Air conditioning systems have become widespread not only in industrialized countries, but also in emerging economies. The main consumers of these systems areChina, theUnited States, Latin America andEurope, and other con...

INFORMATION SYSTEMS IN AVIATION AND ROCKETRY

The "information economy" characterized by one single information space, based on the information infrastructure will dominate in the information society. Due to the inherent globality of space and aviation systems, the...

Download PDF file
  • EP ID EP454479
  • DOI -
  • Views 59
  • Downloads 0

How To Cite

Юліан Михайлович Туз, Антон Валерійович Вдовиченко Вдовиченко (2018). Вимірювання активної потужності реактивного навантаження в широкому діапазоні частот. Інформаційні системи, механіка та керування, 0(18), 5-11. https://europub.co.uk./articles/-A-454479