Virtual Evaluation of Static Structural Analysis of Non- Manifold Assembly of Femur and Implant

Abstract

Engineers apply classical mechanics (statics, dynamics, fluids, solids, thermodynamics, and continuum mechanics) to biological or medical problems. It includes the study of motion, material deformation, flow within the body and in devices, and transport of chemical constituents across biological and synthetic media and membranes. Progress in biomechanics has led to the development of the artificial heart and heart valves, artificial joint replacements, as well as a better understanding of the function of the heart and lung, blood vessels and capillaries, and bone, cartilage, inter-vertebral discs, ligaments and tendons of the musculoskeletal systems. The motivation is in being able to carry out this project to contribute into the orthopedic sector in the areas of pre-surgery, failure analysis, design of prosthesis and hips replacement with the use of finite element modeling. The problem with hip replacement technology is a challenging one and no addition to that effort is a wasted venture. The aim of this work is to carry out virtual Static Structural Analysis on Non Manifold Assembly of Femur and Implant at different body weights using MIMICS and ANSYS softwares for the analysis. Stainless Steel SS316L was used for the implant because of its biocompatibility and strength as stated in literatures. The weights were converted to pressures and were applied on the ball part of the prosthesis. The result obtained showed that the assembly has a good initial stability.

Authors and Affiliations

Gabriel Oladeji Bolarinwa, Sam Omenyi

Keywords

Related Articles

A Literature Survey of Load Forecasting Methods and Impact of Different Factors on Load Forecasting

Load forecasting is vitally important for proper functioning of electrical industry. It has many applications including energy purchasing and generation, load switching, contract evaluation, and infrastructure developme...

Development of Web Server for Accessing Parameters: Review

In an organization there are number of front-ends whose data is send to VME stations and then communicated through RS485 to the PC. The database contains the status of all the front-ends and stored in the XLS file forma...

slugA Survey on State-of-Art Flip-Invariant Descriptors

In image processing , flip operation creates the mirror o f an image. Flip is common copyright infringement technique used in creating near - duplicate videos, since it will not change the video...

Preserving Privacy of Data Using K-Anonymisation and T-Closeness

In recent years, the growth of Electronic Health Record (EHR) technology has increased the amount of clinical data being electronically available. Medical data, scientific documents, and also digitalised patient health...

Review of Integrity Constraint in MySQL

For the semantic correctness of database records, Integrity constraints or data constraints are proper representations of invariant conditions. Constraints can be articulated in declarative languages such as data log, p...

Download PDF file
  • EP ID EP21286
  • DOI -
  • Views 289
  • Downloads 5

How To Cite

Gabriel Oladeji Bolarinwa, Sam Omenyi (2015). Virtual Evaluation of Static Structural Analysis of Non- Manifold Assembly of Femur and Implant. International Journal for Research in Applied Science and Engineering Technology (IJRASET), 3(9), -. https://europub.co.uk./articles/-A-21286