Weighing of risk factors for penetrating keratoplasty graft failure: application of Risk Score System
Journal Title: International Journal of Ophthalmology - Year 2017, Vol 10, Issue 3
Abstract
"AIM: To analyze the relationship between the score obtained in the Risk Score System (RSS) proposed by Hicks et al with penetrating keratoplasty (PKP) graft failure at 1y postoperatively and among each factor in the RSS with the risk of PKP graft failure using univariate and multivariate analysis. METHODS: The retrospective cohort study had 152 PKPs from 152 patients. Eighteen cases were excluded from our study due to primary failure (10 cases), incomplete medical notes (5 cases) and follow-up less than 1y (3 cases). We included 134 PKPs from 134 patients stratified by preoperative risk score. Spearman coefficient was calculated for the relationship between the score obtained and risk of failure at 1y. Univariate and multivariate analysis were calculated for the impact of every single risk factor included in the RSS over graft failure at 1y. RESULTS: Spearman coefficient showed statistically significant correlation between the score in the RSS and graft failure (P<0.05). Multivariate logistic regression analysis showed no statistically significant relationship (P>0.05) between diagnosis and lens status with graft failure. The relationship between the other risk factors studied and graft failure was significant (P<0.05), although the results for previous grafts and graft failure was unreliable. None of our patients had previous blood transfusion, thus, it had no impact. CONCLUSION: After the application of multivariate analysis techniques, some risk factors do not show the expected impact over graft failure at 1y."
Authors and Affiliations
Abdo Karim Tourkmani
Evaluation of artificial tears on cornea epithelium healing
"AIM: To observe the efficacy of different artificial eye drops on corneal epithelium healing in rabbit. METHODS: Thirty-five rabbits with 6 mm diameter central corneal epithelium removed were randomly assigned to six gr...
Managing high risk glaucoma with the Ahmed valve implant: 20 years of experience
"AIM: To estimate the efficacy and safety of the Ahmed implant in patients with high risk for failure after glaucoma surgery. METHODS: In 342 eyes of 342 patients with refractory glaucoma, even with application of medica...
Retinal vessel oxygen saturation in healthy subjects and early branch retinal vein occlusion
"AIM: To measure the retinal oxygen saturation in healthy subjects and early branch retinal vein occlusion (BRVO) in Chinese population. METHODS: The retinal vessel oxygen saturation of the healthy subjects and BRVO pati...
Chandelier-assisted scleral buckling using wide angle viewing contact lens for pseudophakic retinal detachment repair
"AIM: To evaluate a modified technique for scleral buckling (SB) in pseudophakic retinal detachment (RD). METHODS: A retrospective non-comparative study included 21 consecutive eyes with uncomplicated pseudophakic RD tha...
Inhibition of LY294002 in retinal neovascularization via down-regulation the PI3K/AKT-VEGF pathway in vivo and in vitro
"AIM: To investigate the effects of the phosphatidylinositol 3-kinase (PI3K) inhibitor LY294002 on retinal neovascularization (RNV) in the oxygen-induced retinopathy (OIR) mouse model and human umbilical vein endothelial...