A HIGH SENSITIVE MICROWAVE MEASURING DEVICE OF THE MOISTURE CONTENT IN THE NON-POLAR DIELECTRIC LIQUIDS BASED ON AN INHOMOGENEOUS STEP COAXIAL RESONATOR

Abstract

Purpose. Objective is to create a moisture meter for non-polar liquid dielectrics with low volumetric moisture content of more than 10 3 %. Methodology. Moisture measuring is based on dielcometric method. It is implemented as a resonant method of determining a capacitance measuring transducer. Measuring transducer capacitive type has a working and parasitic capacitance. It was suggested the definition of moisture on four of resonance frequencies: when the measuring transducer is turned off, one by one filled with air, «dry» and investigated liquid, to determine the parasitic capacitance of the measuring generator, and the parasitic capacitance of the measuring transducer and humidity. Measurement frequency was increased up to microwave range to increase the sensitivity. Measuring transducer with distributed parameters representing a step heterogeneous coaxial resonator is used by. This measuring transducer has a zero stray capacitance, because the potential electrode has a galvanic connection with an external coaxial electrode. Inductive ties loop is used to neglect parasitic capacitance of the measuring generator, and to increase the quality factor of the system. Measuring moisture is reduced to measuring the two frequencies of resonance frequency and «dry» and investigated liquid. Resonant characteristics transducer in a step inhomogeneous coaxial resonator have been investigated to determine the quality factor of filled with air and transformer oil, and experiments to measure the moisture content in transformer oil have been conducted. Results. Measuring transducer of distributed type is developed and researched – it is step inhomogeneous coaxial resonator. It has a smaller geometric length and larger scatter of the first and second resonant frequencies. Expression is obtained for determination of moisture on the basis of two resonant frequencies. The formula of the two frequencies to determine the moisture is correct. Resonant characteristics are obtained for measuring transducer. Its quality factor has been determined – it does not depend on what it is filled with air or oil. The moisture content in transformer oil for the amount of water to 10-3 % with an error of no more than 6.7 % has been determined. Originality. It has been proposed to use of an inhomogeneous step coaxial resonator as a measuring transducer. Original high sensitive moisture meter for the fluid at rest and flowing fluid with low values of parasitic capacitances has been developed and researched. An original method of determining the moisture by measuring the two frequencies of resonance has been proposed and implemented. Practical value. This meter may be used to determine moisture in any of the non-polar liquid with high speed and accuracy. Moisture meter can be used in electrical engineering, aeronautical engineering, in the chemical and food industries.

Authors and Affiliations

V. V. Rudakov, A. A. Korobko

Keywords

Related Articles

DEVELOPMENT OF METHODS AND MEANS OF COMPUTER SIMULATION FOR STUDYING ARC FURNACE ELECTRIC MODES

Goal. The purpose of the article is the creation of a three-phase instantaneous coordinates Simulink computer model of the power supply and automatic coordinates control system (ACS) of the DSP-200 type arc furnace elect...

MODELING CONTROLLED ASYNCHRONOUS ELECTRIC DRIVES WITH MATCHING REDUCERS AND TRANSFORMERS

Purpose. Working out of mathematical models of the speed-controlled induction electric drives ensuring joint consideration of transformers, motors and loadings, and also matching reducers and transformers, both in static...

HIGH-PERFORMANCE ELECTROMECHANICAL AND ELECTROMAGNETIC PULSE DEVICES FOR DESTRUCTION OF INFORMATION ON DIGITAL DRIVES

It is shown that the most promising way to mechanical destruction of digital information storage is using a pulsed electromechanical and magnetic device and method. The highly efficient autonomous electromechanical and e...

ENERGY EFFICIENCY OF THE DISINFECTION TREATMENT OF LIQUID FOODSTUFFS BY HIGH-VOLTAGE PULSE EFFECTS

Purpose. Experimentally determine the rational modes and energy efficiency of decontamination treatment of flowing food products using high-voltage impulse actions in comparison with traditional pasteurization. Methodolo...

DETERMINATION OF INSULATION PARAMETERS OF CURRENT TRANSFORMERS AT MULTIPLE MEASUREMENTS IN MONITORING SYSTEMS UNDER WORKING VOLTAGE

Features of the data processing procedures of multiple measurements of the dielectric loss tangent of the high-voltage insulation, which are based on the comparison method, were considered. Three procedures were compared...

Download PDF file
  • EP ID EP297727
  • DOI 10.20998/2074-272X.2016.5.08
  • Views 132
  • Downloads 0

How To Cite

V. V. Rudakov, A. A. Korobko (2016). A HIGH SENSITIVE MICROWAVE MEASURING DEVICE OF THE MOISTURE CONTENT IN THE NON-POLAR DIELECTRIC LIQUIDS BASED ON AN INHOMOGENEOUS STEP COAXIAL RESONATOR. Електротехніка і Електромеханіка, 0(5), 51-56. https://europub.co.uk./articles/-A-297727