An Analytical- empirical Calculation of Linear Attenuation Coefficient of Megavoltage Photon Beams

Journal Title: Journal of Biomedical Physics and Engineering - Year 2017, Vol 7, Issue 3

Abstract

Background: In this study, a method for linear attenuation coefficient calculation was introduced. Methods: Linear attenuation coefficient was calculated with a new method that base on the physics of interaction of photon with matter, mathematical calculation and x-ray spectrum consideration. The calculation was done for Cerrobend as a common radiotherapy modifier and Mercury. Results: The values of calculated linear attenuation coefficient with this new method are in acceptable range. Also, the linear attenuation coefficient decreases slightly as the thickness of attenuating filter (Cerrobend or mercury) increased, so the procedure of linear attenuation coefficient variation is in agreement with other documents. The results showed that the attenuation ability of mercury was about 1.44 times more than Cerrobend. Conclusions: The method that was introduced in this study for linear attenuation coefficient calculation is general enough to treat beam modifiers with any shape or material by using the same formalism; however, calculating was made only for mercury and Cerrobend attenuator. On the other hand, it seems that this method is suitable for high energy shields or protector designing.

Authors and Affiliations

F Seif, M J Tahmasebi-Birgani, M R Bayatiani

Keywords

Related Articles

Radiation-induced Non-targeted Effect and Carcinogenesis; Implications in Clinical Radiotherapy

Bystander or non-targeted effect is known to be an interesting phenomenon in radiobiology. The genetic consequences of bystander effect on non-irradiated cells have shown that this phenomenon can be considered as one of...

A Quantitative Investigation on the Effect of Edge Enhancement for Improving Visual Acuity at Different Levels of Contrast

Background: The major limitation in human vision is refractive error. Auxiliary equipment and methods for these people are not always available. In addition, limited range of accommodation in adult people when switching...

The Effect of Gold Nanoparticles on Electrical Impedance of Tissue on Low Frequency Ranges

Introduction: Electrical impedance of tissues on low frequencies includes useful information about functional and structural changes in tissues. This property is used in Electrical Impedance Tomography (EIT) imaging moda...

Brain Volume Estimation Enhancement by Morphological Image Processing Tools

Background: Volume estimation of brain is important for many neurological applications. It is necessary in measuring brain growth and changes in brain in normal/abnormal patients. Thus, accurate brain volume measurement...

Online Estimation of Elbow Joint Angle Using Upper Arm Acceleration: A Movement Partitioning Approach

Estimating the elbow angle using shoulder data is very important and valuable in Functional Electrical Stimulation (FES) systems which can be useful in assisting C5/C6 SCI patients. Much research has been conducted based...

Download PDF file
  • EP ID EP331729
  • DOI -
  • Views 78
  • Downloads 0

How To Cite

F Seif, M J Tahmasebi-Birgani, M R Bayatiani (2017). An Analytical- empirical Calculation of Linear Attenuation Coefficient of Megavoltage Photon Beams. Journal of Biomedical Physics and Engineering, 7(3), 225-232. https://europub.co.uk./articles/-A-331729