Analysis of emergency disconnections of main power lines.

Abstract

Automatic disconnections in trunk transmission lines 750 kv as a result of geomagnetic induction currents is studied The influence of geomagnetic induction currents on emergency switching-off of the main transmission lines is investigated. A mathematical model for the estimation of tension level of the geoelectric field, based on the data of the geomagnetical field oscillation of the Earth is worked out . The model takes into account the conductivity of the earth's crust for each of the regions. The present ed graphs show geoelectric field oscillations for one of emergency outages on 750 kV transmission lines. On the basis of fluctuations studies on the surface potential of the earth on the territory of Ukraine, one can consider as intensive perturbations whose value is greater than 4 V/km. The statistical diagrams of coincidences of the maximum value of the surface potential with the disconnection of power lines are given. In 33 cases on the days of outages we observed strong geomagnetic disturbances, which led to the imposition of a surface potential in the regions where these lines pass. These trips account for 87% of all failures without established causes.

Authors and Affiliations

B. ZHUK, V. V. Kyryk

Keywords

Related Articles

IMPROVING CURRENT PROTECTION AGAINST SHORT CIRCUIT OF SMART-GRID 6–35 KV NETWORK USING STRUCTURAL-INFORMATION METHOD. PART 1. ANALYSIS

A proposed method is presented for methodical improvement of the algorithms of relay pro-tection and automation for the implementation of the concepts of "Smart -grid", "Digital cell", "Digital substation", and "Outsour...

STRUCTURAL REALIZATION OF THE MAXIMUM TORQUE PER AMPERE STRATEGY FOR THE VECTOR SPEED CONTROL SYSTEM OF INDUCTION MOTORS

У роботі запропоновано новий спосіб структурної реалізації стратегії максимізації моменту на ампер в системі регулювання швидкості асинхронного двигуна з векторним керуванням, що відрізняється від типового наявністю ко...

Determination of electromagnetic parameters of the excitation winding and damper system.

The method of synthesis of equivalent circuits turbogenerators was further developed considering various mutual inductive coupling between excitation and damper winding paths through structural detail by providing...

Synthesis of robotic transport control system as a discrete-event object.

An assembly workshop is observed, wherein robotic transport system is used. A workshop’s technological process consists of making up a set of parts in warehouse and their transportation to the assembly places (sectio...

Three-phase converter unit for combined power supply systems of local objects with photovoltaic solar battery.

Combined power supply systems for local objects with a photovoltaic solar battery have a connection to AC grid. At a power of more than 10 kW, the converter unit is three-phase and is used only in the daytime. Increasin...

Download PDF file
  • EP ID EP660515
  • DOI -
  • Views 256
  • Downloads 0

How To Cite

B. ZHUK, V. V. Kyryk (2018). Analysis of emergency disconnections of main power lines.. Наукові праці Донецького Національного Технічного Університету серія: Електротехніка і Енергетика, 1(1), 40-46. https://europub.co.uk./articles/-A-660515