Application of serum plate in the grey area setting of HBsAg ELISA

Journal Title: Chinese Journal of Blood Transfusion - Year 2022, Vol 35, Issue 11

Abstract

Objective To evaluate the necessity and rationality of setting 0.7 CO of the gray area of HBV surface antigen reagent (ELISA) in our laboratory, and to provide the basis for the grey area setting. Methods A total of 60 samples of serum plate were repeatability tested by two kinds of ELISA HBsAg reagents. Based on the test results, C50, C5, C95 concentrations and corresponding S / CO values were calculated, and whether C5 and C95 were within C50±20% was verified. At the same time, the true positive rate and the confirmed positive rate of gray area samples revealed by two reagents were calculated. Results The confirmation results of serum plate were as follows: The C50, C5 and C95 concentrations of reagent A were 0.090 IU/mL, 0.075 IU/mL, 0.105 IU/mL. The true positive rate was 99.1%(436/440), the confirmed positive rate of grey area was37.8%(136/360). The C50, C5 and C95 concentrations of reagent B were 0.112 IU/mL, 0.091 IU/mL, and 0.133 IU/mL; the true positive detection rate was 97.1%(233/240); the confirmed positive rate of grey area was 35.8%(129/360). It was verified that C5 and C95 of reagent A and reagent B were within their respective C50±20%, and the gray areas of the HBsAg ELISA were verified to be effective. Conclusion It is necessary to set the gray area for these two HBsAg ELISA reagents in our laboratory, but the gray area value setting to 0.7 CO is unreasonable. The best gray area value was 0.75 CO in reagent A and 0.63 CO in reagent B.

Authors and Affiliations

Dan SHENG, Kecheng WANG

Keywords

Related Articles

Application and development of biosensors in the detection of transfusion transmitted diseases markers:a review

Blood transfusion is a common therapeutic measure with indispensable role in clinical medicine. However, there is a risk of transmitting diseases during blood transfusion, such as human immunodeficiency virus (HIV), hepa...

Molecular mechanism and bioinformatics analysis of 9 samples with rare RhD variants

Objective To study the molecular mechanism of 9 samples with rare RhD variants and their RhD epitopes and protein structure. Methods The 9 blood samples with rare RhD variants were collected from 210 644 blood donors of...

ABO ambiguous blood types in voluntary blood donors from Putian, Fujian Province: a serology and molecular biology study

Objective To investigate the serological and molecular biology characteristics of ambiguous blood types among voluntary blood donors in Putian, and to file records for relevant donors for future reference in case of thei...

Effect of AB platelet secondary compatible transfusion on the efficacy of matched platelet transfusion

Objective To retrospectively analyze the effect of AB platelet secondary compatible transfusion on the efficacy of matched platelet transfusion. Methods A total of 2 276 cases of platelet transfusion in our hospital were...

Analysis and prospect of platelet compatible transfusion

Platelet compatible transfusion can effectively solve the immune mediated platelet transfusion refractoriness (PTR), save platelet resources and improve blood safety. This paper comments and prospects the compatibility m...

Download PDF file
  • EP ID EP738415
  • DOI 10.13303/j.cjbt.issn.1004-549x.2022.11.020
  • Views 70
  • Downloads 0

How To Cite

Dan SHENG, Kecheng WANG (2022). Application of serum plate in the grey area setting of HBsAg ELISA. Chinese Journal of Blood Transfusion, 35(11), -. https://europub.co.uk./articles/-A-738415