Comparative analysis of risks which are accompanied by the use of typical and boundary gases concentrations for the diagnostics of high voltage transformers

Journal Title: Energetika - Year 2018, Vol 0, Issue 0

Abstract

The aim of the scientific research provided in the article is to increase the operational reliability of high-voltage power transformers by reducing the possible risks when diagnosing high-voltage equipment based on the analysis of gases dissolved in oil. We described the method for determining the boundary (typical) gas concentrations by the integral function method, which is recommended by some existing standards, and the author’s method for determining the boundary concentrations of gases ensuring a minimum of possible economic damage in case of taking erroneous decisions. The analysis of boundary concentrations of gases obtained by the method of integral functions and the method of minimum risk showed that boundary values differ significantly for the same data, depending on the method of determination. To determine the reliability of decision-making we used a comparative analysis of risk values that may arise while making a diagnosis of high-voltage transformers based on the analysis of gases dissolved in oil, the boundary values of gas concentrations obtained by the integral function method and the minimum risk method, as well as the boundary values of gas concentrations regulated by known international and national standards were used. The study has revealed that the use of typical values of gas concentrations obtained by integrated distribution functions is accompanied by one of the highest risk values. The lowest risk value is provided by the boundary concentrations obtained by the minimum risk method. The method proposed for determining the boundary values of gas concentrations, taking into account the influence of the most relevant factors, allows significantly lower the values of possible risks and consequently can increase the operational reliability of high-voltage transformers, especially those that are used outside the normative service life.

Authors and Affiliations

Oleg Shutenko, Olena Proskurnia, Volodymyr Abramov

Keywords

Related Articles

Luminescence of X-ray induced radiation defects in modified lithium orthosilicate pebbles with additions of titanium dioxide

Modified lithium orthosilicate (Li4SiO4) pebbles with additions of titanium dioxide (TiO2) are designed as a possible tritium breeder ceramic for the helium cooled pebble bed (HCPB) test blanket module. Additions of TiO2...

Investigation of the energy efficiency of waste utilization technology, with considering the use of low-temperature separation of the resulting gas mixtures

Currently, there are existing technologies for high-temperature waste disposal, which use the resulting gas as fuel for recycling newly formed waste. However, the composition of waste is not constant, and contents of the...

Study of approaches to incipient fault detection in power transformer by using dissolved gas analysis

To maintain the reliability of power transmission it is important to detect the incipient fault of power transformer as early as possible. If the fault of a power transformer is not detected promptly, it can evolve resul...

Calculation and comparative analysis of the mean energy expended per ion pair by electrons in water and hydroxyl radical

Researches of physical and chemical processes occurring in water during the interaction with particles (electrons, ions, photons, etc.) are interesting for a wide range of physical and applied problems in astrophysics, r...

Rheological study on CO2 hydrate slurries for secondary refrigeration

To help the fight against climate change, the Kigali deal has planned to eliminate hydrofluorocarbon’s use (HFC) in industrial systems. HFCs are powerful greenhouse gases with a high global warming potential. Moreover, H...