Comparison between the Performances of Platinum and Carbon Paste Electrodes for Voltammetric Vitamin C Determination

Journal Title: RECENT - Year 2011, Vol 12, Issue 31

Abstract

Voltammetric and amperometric methods allow fast, sensitive and selective ascorbic acid determination, requiring little or no sample preparation. Voltammetry at various electrodes was used to assess the ascorbic acid content in different media. For differential pulse voltammetry, the oxidation peak of ascorbic acid occurs at about 470 mV on a carbon paste working electrode and at about 530 mV (vs. SCE) on a Pt strip working electrode. A linear dependence between the current intensity measured for the peak height and ascorbic acid concentration was obtained between 0.31 and 20 mM on a Pt working electrode and between 0.07 and 20 mM on a carbon paste electrode. Lower detection limits were obtained with a carbon paste working electrode.

Authors and Affiliations

Aurelia PISOSCHI, Gheorghe NEGULESCU

Keywords

Related Articles

Multicriterial Optimization Applied for Choosing the Measuring Instrument

According to David C. Crosby, "If you don’t know the capability of your measurement system, you don’t know if your measurements, or your products, are good or bad". Starting from this basic it had been made an comparativ...

Evolution of the Solid Fraction at the Solidification of a 0.1 %C Steel

To achieve mathematical models and software for solidification simulation casted pieces it is necessary to know the fraction of the solid variation at solidification. In the case of the alloys form solid solution by soli...

Conceptual Ecodesign for the Product Using Stage

Usually, the environmental impact of a product should be assessed during all the stages of its life cycle. In this paper, the evaluation will focus on the useful life of a product. Some products consume significant resou...

Analysis of the Performance Criteria of Optoelectronic Systems

Analysing the results of the case study, I believe that the optimal choice optoelectronic systems is very important to determine and rank the performance criteria according to their contribution to fulfilling the mission...

The Mathematical Modelling and Computer Simulation of Casting Solidification

The Department of Materials Science from Transilvania University, Faculty of Materials Science & Engineering developed some mathematical models and software for the computer simulation of casting solidification. The...

Download PDF file
  • EP ID EP129419
  • DOI -
  • Views 84
  • Downloads 0

How To Cite

Aurelia PISOSCHI, Gheorghe NEGULESCU (2011). Comparison between the Performances of Platinum and Carbon Paste Electrodes for Voltammetric Vitamin C Determination. RECENT, 12(31), 55-58. https://europub.co.uk./articles/-A-129419