Comparison of efficient of the combined solar collector for energy-efficient buildings for different modes of operation

Abstract

On the whole, alternative energy should contribute to taking the two pressing problems of environmental safety and energy efficiency. Solar energy, as energy resources of the future, has a lot of benefits. It is mainly harmless to people and the environment. It does not distort the landscape. There is no point in exporting or importing it. As for the energy itself, it is both free and renewable, the latter benefit being the most important one. In work paid considerable attention to solar heating systems and proposed to use this solar heating system in energy-efficient homes in Ukraine. This the primary solution may be used for decrease energy consumption of buildings. The overall effectiveness of solar installations is largely dependent on the level of solar energy, which in its turn is strongly dependent on the geographical position. Therefore, special attention is paid to the analysis of the heat flux, came onto the plane solar collector during the experiment, in consequence of changes in the intensity of solar radiation. In the work analysis the efficiency combined heating system in the conditions of southern orientation of the territory and the different modes. According to the study, the findings and recommendations of the use of combined solar heating at increasing the share of solar energy industry and efficiency of such systems in the overall energy balance of the country.

Authors and Affiliations

M. Ulewicz, V. Zhelyh, S. Shapoval, N. Spodyniuk, I. Vengryn

Keywords

Related Articles

Інвестиційний проект реконструкції каналізаційних очисних споруд та будівництва станції виробництва біогазу у м. Львові

This article describes the results of the technical and economic calculations and analysis of the economic efficiency of the project of reconstruction of waste water treatment plant. Lviv and construction of biogas plant...

ДЕФОРМАТИВНІСТЬ ВУЗЛІВ ДЕРЕВ’ЯНИХ КОНСТРУКЦІЙ НА З’ЄДНАННЯХ ТИПУ “СТАЛЬ-ДЕРЕВИНА”

Nowadays design of timber buildings and constructions growth up. It is connected with the dissemination of eco-technologies, efficient energy-saving buildings, rapid constructing, inexpensive solutions and addicting to s...

MODELLING OF REINFORCED CONCRETE BEAMS WITH PRETENSIONED FRP REINFORCEMENT

Traditional building materials are regularly improved, finding new operational characteristics and complementing the quality of technical parameters. For a long time and now as reinforcement of reinforced concrete elemen...

Investigation of indoor air quality and its impact on human activity - case study

This paper presents the partial results of human presence impact on indoor air quality in a monitored office room. Indoor air temperature, relative humidity and carbon dioxide concentration are recorded in the investigat...

Ventilation duct sizing tools - tradition and modernity

One of the most important problems in the hydraulic design of various building services systems is the calculation of the friction factor involved in Darcy-Weisbach equation. Ventilation duct sizing is a good case study,...

Download PDF file
  • EP ID EP230937
  • DOI -
  • Views 91
  • Downloads 0

How To Cite

M. Ulewicz, V. Zhelyh, S. Shapoval, N. Spodyniuk, I. Vengryn (2016). Comparison of efficient of the combined solar collector for energy-efficient buildings for different modes of operation. Вісник Національного університету "Львівська політехніка". Серія "Теорія та практика будівництва", 0(844), 352-355. https://europub.co.uk./articles/-A-230937