Comparison of internal efforts in elements of type trestle pier at the main and emergency load combination

Abstract

By design scheme of berthing facilities trestle of type investigation of structures bearing capacity at influence on it different combinations as the basic load and emergency, including a seismic action was carried out. During calculations results of internal forces and stresses in structures elements are obtained. Comparing them with less affected elements of the pier type trestle type get the data for further work. These results allowed to make the analysis and identify the most vulnerable elements of the pier. Based on these results it can be concluded that the type construction trestle piers erected by in the second half of the XX century, have the right to exist without significant design changes, for sufficiently quality of their survey and absence of significant damage or destruction, in terms of strengthening elements that are required to carry out in accordance with the SBC B.1.1-12:2014 Construction in seismic regions of Ukraine.

Authors and Affiliations

V. P. , Slobodyanuk, K. I. , Anisimov, O. V. , Adamov

Keywords

Related Articles

Optimum marks of porous concrete for walls of civil buildings

A wide range of possible values of average density, strength indicators and thermal conductivity determines the efficiency of the use of porous concrete as a material for the walls of residential and public buildings. An...

Determination of the lattice optimal geometric shape in the combined arch system for circular plan buildings

The methodology of determining the optimal geometric shape of the lattice in the combined arch system was developed under conditions of tensile capacity of all elements of the flexible lattice and the minimum material co...

Renewal of air conditioning system of manufacturing premises

An important priority of the economic policy of Ukraine is the careful use of energy. Therefore, a large-scale energy saving policy is being implemented in the country, and energy efficiency objectives are comprehensive...

calculation of non-homogeneous anisotropic rectangular plates with arbitrary fixation on the contur

For practical applications in engineering are important tables for determining deflections and internal forces of structures. Such tables for the isotropic case under various conditions of plate support on the contour ar...

Determination of the influence of subway on the load-bearing structures of buildings with numerical methods

The article is devoted to numerical investigation of the vibration impact of subway on load-bearing structures of high-rise buildings. Parameters of the dynamic action of the rail transport (train, tram, metro) and the r...

Download PDF file
  • EP ID EP323954
  • DOI -
  • Views 137
  • Downloads 0

How To Cite

V. P. , Slobodyanuk, K. I. , Anisimov, O. V. , Adamov (2017). Comparison of internal efforts in elements of type trestle pier at the main and emergency load combination. Вісник Одеської державної академії будівництва та архітектури, 1(67), 121-126. https://europub.co.uk./articles/-A-323954