COMPUTER SIMULATION OF INTERMITTENT CURRENT MODE OF DC ELECTRIC DRIVE WITH THREE-PHASE CONTROLLED RECTIFIER
Journal Title: Електротехніка і Електромеханіка - Year 2018, Vol 0, Issue 4
Abstract
Introduction. The mode of intermittent current for DC motor with three-phase thyristor rectifier appears in the idle intervals of some mechanisms. Active and passive filters reduce the variable component of the rectified voltage. The capacitance of the capacitors filter is determined by the effective value of the variable component of the rectified voltage. Problem. Necessity of developing an analytical method for calculating the effective value of the variable component of the rectified voltage in the intermittent current mode, taking into account three parameters: the control angle, the electromagnetic time constant of the armature circuit and the load current. Purpose. To determine the dependence of the effective value of the variable component of the rectified voltage for three parameters in theintermittent current mode. Methodology. The effective value of the variable component of the rectified voltage is suggested to be determined through the voltage pulsations factor as the ratio of the effective value of the variable component of the rectified voltage to its constant component. The dependence of the pulsations factor from the parameters of the mode is determined using computer simulation of the mode for intermittent current. Results. The computer model is developed in the software package Simulink, which allows to change each parameter of the mode separately while stabilizing the other two. Numerical dependences of the pulsation factor on each parameter are obtained. The analytical dependence of the voltage pulsations factor on three influencing values was obtained by the method of experiment planning. Originality. For the first time, method has been developed for calculating pulsation factor of the rectified voltage and calculating the effective value of the variable component in the mode of intermittent currents, taking into account three parameters. Practical value. The proposed method will allow to rationally determine the capacity of the capacitors of active and passive filters and increase the efficiency of electromechanical power conversion by reducing the variable component of the rectified voltage.
Authors and Affiliations
Y. V. Kovalova
CAST-FILM POLYMER COMPOSITION DOSING SYSTEM DRIVE CONTROL
Object parameters providing uniformity of polymer composition outflow from the spinneret to the substrate are analyzed. An approach to drive controller construction for a dosing system comprising a lag element is conside...
CHARACTERISTICS OF A 4-PHASE VALVE RELUCTANCE MOTOR WHEN POWERED BY UNCAPACITOR SWITCHBOARD
Purpose. Nowadays more and more in a variety of machines and mechanisms applied switched reluctance motor. When designing these engines solve the problem selection switch. While the switch scheme comprises symmetrical br...
AN IMPROVED CONTROL ALGORITHM FOR «DYNAMIC CAPACITOR» VAR COMPENSATOR
Purpose. Modern approaches of VAR compensation are: using compensators with stepped regulation, STATCOMs, active pow-er filters. Recently, more attention is paid to VAR compensator’s design based on the direct AC / AC co...
ANALYSIS OF THREE-PHASE POWER TRANSFORMER LAMINATED MAGNETIC CORE DESIGNS
Analysis and research into properties and parameters of different-type laminated magnetic cores of three-phase power transformers are conducted. Most of new laminated magnetic core designs are found to have significant s...
STUDYING THE EFFECT OF AN ADDITIONAL ACTIVE RESISTANCE IN THE FIELD WINDING CIRCUIT ON STARTING CHARACTERISTICS OF SALIENT-POLE SYNCHRONOUS MOTORS
On the basis of the developed method for calculating steady-state asynchronous operation modes of salient-pole synchronous motors, a procedure of mathematical modelling of the starting characteristics is proposed. The pr...