Dynastab S: A new concept for high energy fractures of the distal tibia

Journal Title: Ortopedia Traumatologia Rehabilitacja - Year 2004, Vol 6, Issue 4

Abstract

Background. High energy fractures of the distal tibia („pylon fractures”) usually result in severe reduction of the range of motion of the superior ankle joint. If there is severe soft tissue trauma coexisting with the fractures, the possibilities for surgical treatment are limited. Our study examined the suitability of the DYNASTAB S external fixator (for ankle joint stabilization). Material and methods. We studied 25 adult patients (15 men, 10 women), treated from April 2001 to March 2003, to whom the DYNASTAB-S stabilizer was applied for an average of 10.5 weeks.Results. In all patients bone union was achieved, with a good range of motion in the talo-crural joint. All patients tolerated the applied treatment well. The average hospital stay was 9 days. There were 2 cases of transient inflammatory reaction of the skin around the screws, and 1 case of algodystrophy syndrome, which resolved after physical treatment combined with pharmacotherapy.Conclusions. The Dynastab S external fixator is very successful in the treatment of fractures with poor prognosis in traditional methods of conservative and surgical treatment, providing bone union and good functional efficiency of the superior ankle joint. The use of the mechanical joint imitating the movement of the injured ankle joint allows for early joint rehabilitation without loss of stability of the fracture. Adaptation of the device to the operated limb is excellent. The Dynastab S external fixator can be recommended for wider use in the treatment of pylon fractures.

Authors and Affiliations

Jarosław Deszczyński, Janusz Karpiński, Marcin Ziółkowski, Artur Stolarczyk, Robert Surowiecki, Andrzej Stasiak

Keywords

Related Articles

Współczesne możliwości zastosowania ultrasonografii w rehabilitacji narządu ruchu

Zastosowanie ultrasonografii przez fizjoterapeutów nosi nazwę rehabilitacyjnego obrazowania ultrasono­gra­ficznego (ang. Rehabilitative Ultrasound Imaging – RUSI). Jest to procedura stosowana przez fizjoterapeu­tów do oc...

Use of Functional Scores For Assessing Patients Following Total Knee Replacement

This paper discusses key aspects of the use of functional scores, including their reliability conditions, differences between subjective and objective assessment and types. Functional scores used for assessing patients f...

Activity and Quality of Life after Total Hip Arthroplasty

Background. Coxarthrosis is a chronic musculoskeletal condition that causes severe pain and considerable limi­tation of the patient’s motor performance. Total hip arthroplasty is one of the most common and effective meth...

Unilateral and bilateral neurogenic dislocation of the hip joint – which deformity is more difficult to treat?

Purpose: to present and compare the results of treatment of spastic hip dislocation in a group of patients with unilateral or bilateral dislocation. Material: We analyzed a group of 77 patients (109 hips) with a dislocat...

WCZESNA OCENA FUNKCJI STAWU KOLANOWEGO I JAKOŚCI ŻYCIA U PACJENTÓW PO WSZCZEPIENIU ENDOPROTEZY STAWU KOLANOWEGO

Wstęp. Celem badania była ocena funkcji stawu kolanowego oraz zmian w postrzeganej przez pacjentów jakości życia przed operacją endoprotezoplastki stawu kolanowego oraz po czterotygodniowym okresie rehabilitacji pooperac...

Download PDF file
  • EP ID EP56199
  • DOI -
  • Views 120
  • Downloads 0

How To Cite

Jarosław Deszczyński, Janusz Karpiński, Marcin Ziółkowski, Artur Stolarczyk, Robert Surowiecki, Andrzej Stasiak (2004). Dynastab S: A new concept for high energy fractures of the distal tibia. Ortopedia Traumatologia Rehabilitacja, 6(4), 433-440. https://europub.co.uk./articles/-A-56199