Effect on Mechanical Properties of Orthodontic Elastomeric Ligatures on Immersion in Disinfecting Solutions - an in vitro Study

Journal Title: Journal of Advances in Medicine and Medical Research - Year 2016, Vol 18, Issue 4

Abstract

Background and Objectives: Cold water disinfection can damage the elastomeric material, cross contamination in handling elastomeric ligatures is a serious concern in the orthodontic office. In addition, elastomeric strips with enough ligatures for both arches of a single patient are produced by most manufacturers. Thus, cross -contamination can occur in remaining ligatures if an entire strip is not used at once. In this investigation effect on tensile strength on short to medium exposure of elastomeric ligatures to disinfection solution and in turn its effect on force delivery is studied. Aims and Objectives: Effect of extended exposure to disinfection solutions on tensile load at failure of different orthodontic elastomeric ligatures is assessed. Materials and Methods: Orthodontic elastomeric ligatures were obtained from 5 manufacturers; 3M Unitek, Ormco, Ortho organizer, GAC, T P Orthodontics. 3 Disinfectant solutions used were Glutarex-3M Unitek, Cidex-Johnson and Johnson and Cidex OPA- Johnson and Johnson. From each manufacturer, ten orthodontic elastomeric ligatures will be exposed to each disinfectant solution with exposure times of 30 minutes, 1 hour, 12 hour and 24 hours. Ten unexposed elastomeric ligatures from each manufacturer will also be tested which will act as control group. Ligatures were stretched in custom made jig of a universal testing machine (INSTRON) until they fractured to determine the tensile load failure. Maximum tensile load were recorded. The tensile load at failure was used as an analog to the clinical situation of the ligature breakage during tie-in. Results and Conclusions: Three-way ANOVA showed significant differences (P < .0001) not only within manufacturer and time of exposure but also between disinfectants (P < .001). Significant interactions (P < .0001) were observed between manufacturer and time and between disinfectant and time. Greater significant changes were seen in tensile load at failure for all 5 manufactures ligatures in Cidex solution whereas changes were less significant in Glutarex and Cidex OPA solution. The ligatures from all companies showed significantly different failure loads from each other, with the ligatures from 3M exhibiting the greatest tensile load at failure and those from Ortho Organizer, the least. Elastomeric Ligatures Tensile Load at Failure Followed the Pattern: 3M Unitek _ GAC _ Ormco _ T P Orthodontics _ Ortho organizer. Tensile load to failure of elastomeric ligatures, compared to unexposed specimens changed when exposed to disinfectant solution for as little as 30 minutes.

Authors and Affiliations

Manvi Singh

Keywords

Related Articles

Does Patient Position Influence the Results of Three-dimension High Resolution Ano-rectal Manometry?

Aims: Anorectal manometry is the current gold standard to explore anorectal functional disorders. Recently, three-dimensional high-resolution anorectal manometry (3DHRAM) was developed. However, although procedures are u...

Electron Beam Irradiation of Resin Luting Agents - a Cytotoxic Evaluation on Dental Pulp Cells

Aim: The aim of this study was to evaluate the cytotoxicity of three resin luting agents Rely X luting cement, Rely X luting 2 cement and Clearfil SA luting cement before and after electron beam irradiation. Materials a...

Chordoma of the Cervical Spine: A Case Report and Review of Literature

Chordomas are rare low to intermediate grade malignant tumours derived from the notochordal remnants. Their location in the cervical spine is exceptional. The clinic radiologic features, anatomopathologic aspects, diagno...

Severe Cognitive Dysfunction and Occupational Extremely Low Frequency Magnetic Field Exposure among Elderly Mexican Americans

Aims: This report is the first study of the possible relationship between extremely low frequency (50-60 Hz, ELF) magnetic field (MF) exposure and severe cognitive dysfunction. Earlier studies investigated the relationsh...

Studies on Parasitaemia, Immunologic and Virologic Indices among Pregnant Mothers Living with HIV Attending Aminu Kano Teaching Hospital, Kano State-Nigeria

Aims: To determine the presence of malaria parasite and also examine the relationship between HIV infection and the severity of malaria. Study Design: A hospital based prospective cohort study was carried out among 200 p...

Download PDF file
  • EP ID EP340901
  • DOI 10.9734/BJMMR/2016/28630
  • Views 59
  • Downloads 0

How To Cite

Manvi Singh (2016). Effect on Mechanical Properties of Orthodontic Elastomeric Ligatures on Immersion in Disinfecting Solutions - an in vitro Study. Journal of Advances in Medicine and Medical Research, 18(4), 1-9. https://europub.co.uk./articles/-A-340901