Effect on Mechanical Properties of Orthodontic Elastomeric Ligatures on Immersion in Disinfecting Solutions - an in vitro Study

Journal Title: Journal of Advances in Medicine and Medical Research - Year 2016, Vol 18, Issue 4

Abstract

Background and Objectives: Cold water disinfection can damage the elastomeric material, cross contamination in handling elastomeric ligatures is a serious concern in the orthodontic office. In addition, elastomeric strips with enough ligatures for both arches of a single patient are produced by most manufacturers. Thus, cross -contamination can occur in remaining ligatures if an entire strip is not used at once. In this investigation effect on tensile strength on short to medium exposure of elastomeric ligatures to disinfection solution and in turn its effect on force delivery is studied. Aims and Objectives: Effect of extended exposure to disinfection solutions on tensile load at failure of different orthodontic elastomeric ligatures is assessed. Materials and Methods: Orthodontic elastomeric ligatures were obtained from 5 manufacturers; 3M Unitek, Ormco, Ortho organizer, GAC, T P Orthodontics. 3 Disinfectant solutions used were Glutarex-3M Unitek, Cidex-Johnson and Johnson and Cidex OPA- Johnson and Johnson. From each manufacturer, ten orthodontic elastomeric ligatures will be exposed to each disinfectant solution with exposure times of 30 minutes, 1 hour, 12 hour and 24 hours. Ten unexposed elastomeric ligatures from each manufacturer will also be tested which will act as control group. Ligatures were stretched in custom made jig of a universal testing machine (INSTRON) until they fractured to determine the tensile load failure. Maximum tensile load were recorded. The tensile load at failure was used as an analog to the clinical situation of the ligature breakage during tie-in. Results and Conclusions: Three-way ANOVA showed significant differences (P < .0001) not only within manufacturer and time of exposure but also between disinfectants (P < .001). Significant interactions (P < .0001) were observed between manufacturer and time and between disinfectant and time. Greater significant changes were seen in tensile load at failure for all 5 manufactures ligatures in Cidex solution whereas changes were less significant in Glutarex and Cidex OPA solution. The ligatures from all companies showed significantly different failure loads from each other, with the ligatures from 3M exhibiting the greatest tensile load at failure and those from Ortho Organizer, the least. Elastomeric Ligatures Tensile Load at Failure Followed the Pattern: 3M Unitek _ GAC _ Ormco _ T P Orthodontics _ Ortho organizer. Tensile load to failure of elastomeric ligatures, compared to unexposed specimens changed when exposed to disinfectant solution for as little as 30 minutes.

Authors and Affiliations

Manvi Singh

Keywords

Related Articles

Prolactin Levels in Brazilian Patients Evaluated Because of Weight Gain: A Correlation with the Anthropometric and Biochemical Profiles?

Aims: To investigate if basal measures of serum prolactin correlate with biochemical and anthropometric data of Brazilian patients. Methodology: This study consists of a cross-sectional evaluation of basal serum prolac...

Peripheral Cemento-ossifying Fibroma -treatment and Follow Up of a Recurrent Case

Peripheral cemento-ossifying fibroma is a non neoplastic growth of soft tissue which often arises from the interdental papilla and is mostly seen in teenagers and young adults. Here we discuss a case of peripheral ceme...

An Investigation of the Retinal Layers in an Experimental Model of Multiple Sclerosis; a Histopathological and Immunohistochemical Study

Background: Animal model of multiple sclerosis is a demyelinating and inflammatory disorder of central nervous system and eye. Histological evaluation in eyes in experimental autoimmune encephalomyelitis (EAE) models dem...

Dyslipidaemia in Hypertensives in South-South Nigeria

Background: There is a strong relationship between hypertension and dyslipidaemia, and both can increase the risk of developing coronary heart disease. Methods: A total of One hundred and eighty (180) participants were r...

A Non-healing Ulcer with Unilateral Facial Palsy

Introduction: Oral cavity is a hub for millions of microorganisms which are non pathogenic, but in immunocompromised states, plethora of diseases emerge which may be the most rarest and fatal. Mucormycosis has emerged as...

Download PDF file
  • EP ID EP340901
  • DOI 10.9734/BJMMR/2016/28630
  • Views 48
  • Downloads 0

How To Cite

Manvi Singh (2016). Effect on Mechanical Properties of Orthodontic Elastomeric Ligatures on Immersion in Disinfecting Solutions - an in vitro Study. Journal of Advances in Medicine and Medical Research, 18(4), 1-9. https://europub.co.uk./articles/-A-340901