Effects of Molecular Weight and Loading on Matrix Metalloproteinase-2 Mediated Release from Poly(Ethylene Glycol) Diacrylate Hydrogels
Journal Title: The AAPS Journal - Year 2012, Vol 14, Issue 3
Abstract
Herein, we report on continued efforts to understand an implantable poly(ethylene glycol) diacrylate (PEGDA) hydrogel drug delivery system that responds to extracellular enzymes, in particular matrix metalloproteinase-2 (MMP-2) to provide controlled drug delivery. By attaching peptide as pendant groups on the hydrogel backbone, drug release occurs at an accelerated rate in the presence of active protease. We investigated MMP-2 entry and optimized parameters of the drug delivery system. Mesh size for different PEGDA molecular weight macromers was measured with PEGDA 3,400 hydrogels having a mesh size smaller than the dimensions of MMP-2 and PEGDA 10,000 and PEGDA 20,000 hydrogels having mesh sizes larger than MMP-2. Purified MMP-2 increased release of peptide fragment compared to buffer at several loading concentrations. Cell-stimulated release was demonstrated using U-87 MG cells embedded in collagen. GM6001, an MMP inhibitor, diminished release and altered the identity of the released peptide fragment. The increase in ratio of release from PEGDA 10,000 and PEGDA 20,000 hydrogels compared to PEGDA 3,400 hydrogels suggests MMP-2 enters the hydrogel. PEGDA molecular weight of 10,000 and 15 % (w/V) were the optimal conditions for release and handling. The use of protease-triggered drug delivery has great advantage particularly with the control of protease penetration as a parameter for controlling rate of release.
Authors and Affiliations
Amy E. Ross, Mary Y. Tang, Richard A. Gemeinhart
Current Industrial Practices in Assessing CYP450 Enzyme Induction: Preclinical and Clinical
Induction of drug metabolizing enzymes, such as the cytochromes P450 (CYP) is known to cause drug-drug interactions due to increased elimination of co-administered drugs. This increased elimination may lead to significan...
Small Molecule Specific Run Acceptance, Specific Assay Operation, and Chromatographic Run Quality Assessment: Recommendation for Best Practices and Harmonization from the Global Bioanalysis Consortium Harmonization Teams
Consensus practices and regulatory guidance for liquid chromatography-mass spectrometry/mass spectrometry (LC-MS/MS) assays of small molecules are more aligned globally than for any of the other bioanalytical techniques...
Metabolism of GTI-2040, a phosphorothioate oligonucleotide antisense, using ion-pair reversed phase high performance liquid chromatography (HPLC) coupled with electrospray ion-trap mass spectrometry
GTI-2040 is a 20-mer phosphorothioate oligonucleotide, which is complementary to the messenger ribonucleic acid (mRNA) of the R2 subunit of ribonucleotide reductase. This study characterized both the in vivo and in vitro...
High-Throughput screeening assays for CYP2B6 metabolism and inhibition usuing fluorogenic vivid substrates
CYP2B6 is a highly polymorphic P450 isozyme involved in the metabolism of endo-and xenobiotics with known implications for the activation of many procarcinogens resulting in carcinogenesis. However, lack of validated hig...
Critical Variables Associated with Nonbiodegradable Osmotically Controlled Implants
Osmotically controlled implants yield precise zero-order drug delivery kinetics and are utilized in a number of applications. The implants deliver drugs for extended periods (weeks to years) and exhibit good in vivo/in v...