Abstract

The purpose of this article is to estimate the effect of geometric imperfections on critical loads. Special attention was paid to trusses subjected to large displacement gradients and vulnerable to stability loss due to snapping. The article uses the Lagrangian description for geometric nonlinearities. The truss stability analysis was performed using the Finite Element Method. The equilibrium path was determined using the scalar current parameter of stiffness and method of arc length constant.

Authors and Affiliations

Wojciech Mochocki, Paulina Obara, Urszula Radoń, Paweł Zabojszcza

Keywords

Related Articles

WORKING PARAMETERS OF GAS HEAT PUMP IN USE WITH LOW-POTENTIAL GEOTHERMAL ENERGY

The article presents the operating parameters of the heat pump for gas with low potential geothermal energy. It describes the measurement device and implementations of the experimental measurements resulted in a database...

METHODS AND DIAGNOSTIC TECHNIQUES USED TO ANALYSE THE TECHNICAL STATE OF REINFORCED CONCRETE STRUCTURES

The paper presents the problems concerning the principles of developing expertise and performing tests on reinforced concrete structures. The situations that justify the need to provide expertise, the subject of which ar...

IMPLEMENTATION OF THE GENERALIZED VISCOELASTIC HUET-SAYEGH AND BURGERS MODEL TO DETERMINE THE STIFFNESS MODULUS OF ASPHALT CONCRETE

The aim of this paper is to compare the possibility of application of two physical models, namely generalized Huet- Sayegh and Burgers model to describe the changes in stiffness modulus of asphalt concrete. Both models m...

THE INFUENCE OF BOUNDARY CONDITIONS ON THE SAFETY OF STEEL TRUSSES SUBJETED TO HIGH TEMPERATURES

The study provides an analysis of three trusses that differed only with respect to support. All trusses were analyzed for normal and accidental design cases, latter under fire load. A standard fire curve was adopted, and...

MOISTURE SUSCEPTIBILITY OF WARM MIX ASPHALT CONCRETE CONTAINING SYNTHETIC ZEOLITE

The primary objective of this study was to perform a laboratory testing to determine the moisture sensitivity of an asphalt concrete produced in warm mix asphalt technology (WMA) with the addition of the synthetic zeolit...

Download PDF file
  • EP ID EP245302
  • DOI -
  • Views 122
  • Downloads 0

How To Cite

Wojciech Mochocki, Paulina Obara, Urszula Radoń, Paweł Zabojszcza (2017). EFFECTS OF SINGLE-LAYER TRUSS DOME GEOMETRY ON CRITICAL LOAD CAPACITY. Structure and Environment, 0(3), 152-164. https://europub.co.uk./articles/-A-245302