Establishment and preliminary verification of a highly sensitive nucleic acid extraction method for OBI detection

Journal Title: Chinese Journal of Blood Transfusion - Year 2024, Vol 37, Issue 2

Abstract

Objective To establish and verify a new nucleic acid extraction method for OBI detection with large volume and high sensitivity, and apply it in the quantitative determination of OBI samples with low viral load. Methods The method for nucleic acid extraction with large volume was established based on the method of Roche nucleic acid detection kit. HBV standards were configured into 10 000 IU/mL, 1 000 IU/mL, 100 IU/mL, 10 IU/mL and 1 IU/mL respectively, and nucleic acid was extracted from the 10 mL standards by magnetic beads. CT values of each concentration were detected by fluorescence quantitative PCR and each concentration gradient was detected in parallel duplicates. The logarithm of virus concentration was taken as the X-axis and the average CT values of two tests were taken as the Y-axis to construct the fluorescence quantitative standard curve and regression equation. Three repeated experiments were conducted to verify the stability of the method. This method was used to extract nucleic acid from OBI samples with low viral load, and fluorescence quantification was performed. Results The amplification efficiency of fluorescence quantitative standard curves ranged from 90% to 105%, and the regression equation was greater than 0.99. The variation coefficients of variation of CT values were 0.63%, 0.78%, 1.52%, 1.36% and 0.78%, respectively. This method can extract nucleic acid from OBI samples with viral load of 1 IU/mL for quantification. Conclusion The detection limit of HBV nucleic acid quantitative detection system can reach 1 IU/mL, and it has strong stability and high sensitivity, which can be used for the quantitative detection of OBI with low viral load.

Authors and Affiliations

Wenbo GAO, Bo HE, Rongsong DU, Fenfang LIAO, Junmou XIE, Min WANG, Hao WANG

Keywords

Related Articles

Effect of phenotypes of Duffy blood group on chemokine storage and chemokine scavenging function of erythrocytes

Objective To investigate the effect of phenotypes of Duffy blood group on chemokine storage and chemokine scavenging function of erythrocytes. Methods Twenty-four erythrocyte samples were collected and tested Duffy blood...

Development of a national health standard: Guideline for pediatric transfusion

Children and adults differ significantly in physiology, biochemistry and immune function, which leads to significant differences in blood transfusion strategies between children and adults. To guide the clinical transfus...

Mechanism and transfusion strategy of immunogenic platelet transfusion refractoriness

Platelet transfusion is an irreplaceable method to treat patients with platelet reduction in Hematology Department and Oncology Department. However, immunogenic platelet transfusion refractoriness is a huge challenge to...

Quality of medicinal maltose as a excipient in the production of blood products: a comparative study

Objective To comprehensively compare the quality and filtration efficiency of medicinal maltose between two domestic manufacturers(B, C) and one foreign manufacturer(A), compare their product quality as an excipient for...

Risk factors of red blood cell infusion in very low/ultra-low birth weight neonates with respiratory distress syndrome

Objective To investigate the risk factors of red blood cell transfusion frequency (fRBCT) toward newborns with very/extremely low birth weight (V/ELBW) who experienced <32 weeks of gestational age and were complicated wi...