Evaluation of out of field dose and comparison of dose to healthy tissue between VMAT and IMRT plans.
Journal Title: International Journal of Medical Science And Advanced Clinical Research (IJMACR) - Year 2019, Vol 2, Issue 3
Abstract
Background: Purpose of this study was to evaluate out of field dose calculation accuracy against measured dose and comparing the dose to healthy tissue between VMAT and IMRT plans. Methods and materials: We created a plan with various field sizes to deliver 1Gy dose at 1.58cm in a homogeneous phantom. The calculated dose along the central axis at three depths 1.58cm, 5.0cm and 10.0cm was noted down. Calculated monitor unit was delivered and measured. Dose difference between calculated and measured was found. Ten patients with prostate cancer were selected to evaluate healthy tissue dose with VMAT and IMRT plans. Difference between VMAT and IMRT plans was compared statistically. Results: The deviation between calculated and measured was lesser than 1% within the field. From field edge to 5cm the maximum deviation was -36%, -28% and -15% at Dmax, 5cm and 10cm depths respectively among all points. For larger field size the percentage of error was larger. VMAT controlled the higher doses to healthy tissue within the treatment field along with low and intermediate doses to tissues out of the treatment field (p<0.002). Conclusion: Out of field dose calculation accuracy was reduced for larger field size. VMAT can control dose to healthy tissue volume and it can help to reduce secondary cancer risk.
Authors and Affiliations
Jayapalan Krishnan
Comparative Study of Open & Close Technique of Trocar Insertion for Elective Laparoscopic Cholecystectomy
Introduction: There are mainly two techniques by which first trocar can be inserted. First is the close technique; where a spring loaded verses needle is placed intra abdominally without the aid of direct vision and the...
A Comparative Study Between 0.5% Bupivacaine With Clonidine And 0.5% Bupivacaine Alone For Supraclavicular Brachial Plexus Block In Upper Limb Surgeries
Background:Supraclavicular brachial plexus block provides safe, effective, low cost anaesthesia with excellent post-operative analgesia. The current study was an attempt to compare Bup...
A Comparative Study between Suction Evacuation and Manual Vacuum Aspiration for First Trimester MTP
Background: There are four main methods for safe pregnancy termination– D & E, S & E by electric suction machine, MVA, and medical abortion by misoprostol and mifepristone Objective :To find out the efficacy of MVA, its...
Efficacy of Cefazolin and Cefotaxime in the treatment of mandibular fractures and teeth involved- A comparative study.
Aim: The purpose of this study is to establish a relationship between mandibular fracture sites, vitality of teeth in the line of fracture, displacement of the fractured segments treated with open reduction and fixation...
A Case report : Magnetic resonance imaging (MRI), and Magnetic resonance cholangiopancreatography (MRCP) in Diagnosis of Biliary Microhamartomas
Introduction Biliary hamartomas, which are known as von Meyenburg complexes (VMCs), are benign liver malformations. They histologically include cystic dilated bile ducts which are surrounded by numerous fibrous stroma[1,...