Investigation of the effect of coagulation with high-energy methods of hemostasis implementation on the resected liver surface (experimental research)

Journal Title: Медичні перспективи - Year 2018, Vol 23, Issue 3

Abstract

The peculiarity of using high-energy methods to implement hemostasis is in difficulty of comparing the degree of exposure to high temperature with the achievement of the desired effect, at the same time, excessive temperature in the area of impact leads to the formation of a layer of carbonized tissues or their evaporation. In order to analyze the peculiarities of changes in the liver parenchyma after coagulation with high-energy methods of hemostasis, an experiment that provided liver resection with coagulation of the resection surface using convection-infrared thermosurgical technology in a temperature mode of 600°C, bipolar electro-coagulation and high-frequency electric welding of living biological tissues was performed. The study analyzed the results of experimental studies on 25 outbred rabbits of different sex and age, weighing from 3350.0 g to 4180.0 g. Depending on the use of the high-energy coagulation method, 3 groups were formed: group 1 - high-frequency electric welding of living biological tissues; group 2 - bipolar electro-coagulation; group 3 - convection-infrared thermo¬surgical technology at a temperature mode of 600°C. The data of histological research were analysed. Statistical analysis was performed using SPSS Statistics. Studies have found that the average trend of the thickness of the disaggregation/disintegration zone is 1936 (1630.83-2523) μm in the 1st group, 648 (508.33-734.33) μm in the 2nd group and 470.6 (453.5-507) μm in the 3rd group. The zone of compacted parenchyma: the 1st group – 2732 (2591.5-2798.5) μm, the second group 4538 (4421.5-4687.5) μm (p=0.001). The results of the study indicate that the use of convection-infrared thermosurgical technology in a temperature mode of 600°C has a less destructive effect on the surrounding tissues as compared with bipolar electrocoagulation and high-frequency electric welding of biological tissues.

Authors and Affiliations

O. P. Ternavskyi

Keywords

Related Articles

Optimization of analitycal control over residues of active ingridients of modern pesticides in reservoirs water

A highly sensitive and selective method of pyraclostrobin, boscalid, tebufenpyrad and prohexadione-calcium determination under their combined presence in water sample, using high-performance liquid chromatography was dev...

Muscle dysfunction in tension-type headache in adolescents and methods of its correction

The aim of our study was to investigate the value of myofascial disorders in adolescents with tension-type headaches and evaluation of effectiveness of their treatment using non-drug therapies. A total of 320 adolescents...

Practice of implementation of innovative means of teaching in forming of preventive thinking in students of higher medical educational establisments

The problem of construction of a holistic methodological system of training future doctors considered in the article, is impossible outside the context of integration processes taking place in modern education and needs...

Экспрессия CD117 на бластных клетках при острой миелоидной лейкемии

Метою представленої роботи був аналіз частоти експресії антигена CD117 (c-KIT) на бластних клітинах при гострій мієлоїдній лейкемії (ГМЛ), оцінка наявності залежності між експресією с-КІТ та варіантом лейкозу згідно з ФА...

Клінічний випадок виразкової хвороби дванадцятипалої кишки з перфорацією у породіллі після планового кесаревого розтину

Язвенная болезнь желудка или двенадцатиперстной кишки с перфорацией - тяжелое, угрожающее смертью осложнение язвенной болезни, особенно у беременных или в послеродовом периоде. Возникновение данного осложнения в послерод...

Download PDF file
  • EP ID EP439426
  • DOI 10.26641/2307-0404.2018.3.147961
  • Views 86
  • Downloads 0

How To Cite

O. P. Ternavskyi (2018). Investigation of the effect of coagulation with high-energy methods of hemostasis implementation on the resected liver surface (experimental research). Медичні перспективи, 23(3), 78-83. https://europub.co.uk./articles/-A-439426