Material compatibility of human albumin
Journal Title: Chinese Journal of Blood Transfusion - Year 2023, Vol 36, Issue 8
Abstract
Objective To investigate the compatibility of human albumin and its internal packaging materials of Sinopharm Lanzhou Biopharmaceutical Co., Ltd. Methods One batch of inner packaging materials (medium borosilicate glass-molded injection bottle and halogenated butyl rubber plug for injection) was extracted with 4 extraction solvents to conduct the toxicological evaluation of potential inner packaging extracts. Through the simulated acceleration test, the trend analysis of the elements in the sample and the inner surface of the glass bottle were observed, and the routine drug inspection items during the long-term stability test process were determined. Results The detection results of the leaching elements of the internal packaging materials did not exceed the limit of 50%, and the organic matter safety threshold (margin of safety, MOS) was greater than 1.0, indicating that both the leaching elements and the organic matter had no safety risk to the user under the current exposure. The results of the simulated acceleration test show that the drug will not have the risk of peeling tablets after the long-term stability condition was placed for a period of time, and the routine inspection items of the long-term stability test drugs all meet the requirements of the pharmacopoeia. Conclusion The inner packaging material has no significant impact on the quality of drugs and has good overall compatibility, making it suitable for packaging human albumin.
Authors and Affiliations
Yali WANG, Junhui WEI, Meichun YANG, Xiaojuan ZHOU, He REN, Sha LI, Nan XIE
Analysis of ABO gene mRNA expression in peripheral blood of patients with acute myeloid leukemia
Objective To investigate the expression characteristics of ABO gene mRNA in peripheral blood of patients with acute myeloid leukemia. Methods The RNA-seq data of acute myeloid leukemia in TCGA database and the whole bloo...
Dentification and blood transfusion therapy of anti-C, e alloantibodies with anti-e, Jkb mimicking alloantibodies
Objective To investigate the differential diagnosis of 1 anti-C, e alloantibodies combined with anti-e, Jkb mimicking alloantibodies by absorption-elution test and titer integral method. Methods ABO, Rh and Kidd blood gr...
The renoprotective effect of Salvia miltiorrhiza injection on HBOC-CHP01 resuscitated haemorrhagic shock rats
[Objective] To investigate the protective effect of Salvia miltiorrhiza injection (SMI) on the kidneys of HBOC-CHP01 resuscitated haemorrhagic shock rats. [Methods] A 50% haemorrhagic shock rat model was established, wit...
Traceability of syphilis antibody detection in preserved samples
Objective To investigate whether the current retention methods in blood stations can fully meet the traceability requirements of blood test results by analyzing the traceability of retained samples for syphilis antibody...
Evaluation for the performance of HIV Ag/Ab assay based on ECLIA in blood screening
Objective To evaluate the performance of electrochemiluminescence immunoassay (ECLIA) in detecting HIV antigen/antibody in blood screening. Methods A total of 128 donors, reactive to anti-HIV(ELISA)testing, from Septembe...