A PERFORMANCE OF A WINDOW AIR CONDITIONER USING ALTERNATIVE REFRIGERANTS R22 AND R290

Abstract

 In this paper, simulation studies of a one TR window air conditioner were carried out with three different mixtures of R22 and R290 M1 (50-50) %, M2 (25-75) % and M3 (75-25) %. Performance parameters like refrigerant mass flow rate, refrigerant capacity, compressor power, C.O.P, condenser inlet temperature, condenser outlet temperature, capillary tube inlet temperature and compressor shell inlet temperature were analyzed at varying conditions, evaporator temperature varied from 60C to120C and condenser temperature varied from 400C to 550C and results were analyzed. Performance parameters of R22 and R290 are compared using CYCLE _D software. Simulation results show that R290 has a maximum mass flow rate. Only a marginal variation of capacity is observed with all working fluids. The condenser inlet temperature is minimum for R290 and maximum for R22. Condenser outlet temperature variation is marginal for all refrigerants. R290 has a minimum power consumption and maximum C.O.P. The simulation results show that the use of hydrocarbon refrigerant (R290) improves the performance of window air conditioner.

Authors and Affiliations

Dr. B. Sachuthananthan,

Keywords

Related Articles

A Survey on Embedded Extended Visual Cryptography Scheme

For the safeguard of digital contents from being intercepted by unauthorised parties is a very serious issue in information security.Visual cryptography is the art of securing information by concealing the secret image...

 A New Simple UV Spectrophotometric Determination of Paliperidone Palmitate in Tablets

 A simple ultra violet spectrophotometric method for the analysis of paliperidone palmitate. The chemicals and reagents were prepared for DDQ and WFB methods. Paliperidone Palmitate obeys Beer’s law between the ran...

 OFDM-DCT ROBUST CHANNEL SIMULATION

 Multi-Carrier Modulation is a technique for data-transmission by dividing a high-bit rate data stream is several parallel low bit-rate data streams and using these low bit-rate data streams to modulate several car...

 Finite Element Analysis of I.C Engine Connecting Rod: A Review

 The main objective of this paper is to proposed a weight reduction opportunities for a production cast iron connecting rod. We are taking different types of connecting rod made of cast iron and steel alloys materi...

ESTIMATING PERFORMANCE OF AIR - COOLED SCREW CHILLER BY LOWERING CONDENSOR TEMPERATURE

This paper presents performance enhancement of air - cooled screw chiller by using cooling tower exhaust air. The chiller was tripping in peak summer on high discharge pressure. After finding out the reason a addit...

Download PDF file
  • EP ID EP123395
  • DOI 10.5281/zenodo.159208
  • Views 62
  • Downloads 0

How To Cite

Dr. B. Sachuthananthan, (30).  A PERFORMANCE OF A WINDOW AIR CONDITIONER USING ALTERNATIVE REFRIGERANTS R22 AND R290. International Journal of Engineering Sciences & Research Technology, 5(10), 27-32. https://europub.co.uk./articles/-A-123395