Noninvasive Blood Pressure Measurement In Newborn

Journal Title: Gujarat Medical Journal - Year 2018, Vol 73, Issue 2

Abstract

INTRODUCTION : Non invasive techniques estimate blood pressure by analysing changes in flow produced by compressing an artery in an extremity and monitoring an effect related to compression either by palpation or auscultation assessment or with some externally placed transducer. AIMS AND OBJECTIVES : To study blood pressure measurement in neonates by indirect oscillometric method and pulse oximeter and to compare the both. MATERIALS AND METHODS : This prospective study was conducted on 100 cases selected from L.G. Hospital. 50 neonates from NICU and 50 from postnatal wards were selected. Neonates requiring inotropes, crying neonates and congenital anomalies like CHD were excluded from the study. With an appropriate size cuff, blood pressure was recorded in neonates using indirect oscillometric method and pulse oximeter applied. Pressure was raised in 10mm increments every 5 seconds and the pressure at disappearance and reappearance of plethysmogram was noted and compared with blood pressure. RESULTS : Mean systolic blood pressure in 50 sick and healthy term neonates by NIBP was 60.80+/-11.68 and 69.74+/- 8.55 mm of Hg respectively. Mean pressure of reappearance of BP in sick and healthy term neonates by pulse oximeter was 62.62+/- 12.68 and 73.36+/- 12.34 mm of Hg respectively. Blood pressure is affected by gestational age in weeks. It is lower in premature infants than full term infants. CONCLUSION : Systolic BP correlated better with pulse oximeter BP recording taken at reappearance (RP) plethysmogram. This method of systolic blood pressure measurement is simple, non invasive, accurate and reliable.

Authors and Affiliations

Unmesh Upadhyay, Harish Parikh, Hetal Vora

Keywords

Related Articles

Vertigo Patients In ENT Opd- Study Of 200 Cases

AIM : The aim of this study was to analyze the 200 vertigo patients presenting to ENT opd at ESIC Model Hospital Bapunagar, Ahmedabad having actual ENT cause of vertigo and other medical causes of vertigo and their manag...

A Clinical Study : Role of Flexible Fiberoptic Bronchoscopic Biopsy in Diagnosis of Lung Cancer

Fiberoptic bronchoscopy is very safe and highly sensitive investigation for patients suspected of having lung cancer. It allows one to visualize the tracheobronchial tree and perform a variety of diagnostic and therapeut...

Pre-Operative concerns of a patient in a Rural setup :RURAL SETUP: An Indian Perspective

Objective : To identify and appraise the concerns different patients have prior to undergoing surgery in a rural set up. Method : In this prospective survey, 207 patients completed a questionnaire regarding their concern...

Have you Encountered patients of Spinal Cord injury with shooting BP on 3rd/4th day?? A Review Article on Autonomic Dysreflexia

Autonomic dysreflexia(AD) is a potentially life threatening medical emergency in polytrauma patients affecting individuals with spinal cord injury (SCI) above major splanchnic outflow (T6 or above). AD occurs due to wid...

A study of Endometrial Pathology in abnormal uterine bleeding

ABSTRACT Introduction : - Abnormal Uterine Bleeding is a commonest symptom in gynecology opd. - Endometrial curettage is a diagnostic step in AUB. - This study was done to evaluate Histopathology of endometrium to identi...

Download PDF file
  • EP ID EP431441
  • DOI -
  • Views 122
  • Downloads 0

How To Cite

Unmesh Upadhyay, Harish Parikh, Hetal Vora (2018). Noninvasive Blood Pressure Measurement In Newborn. Gujarat Medical Journal, 73(2), 59-62. https://europub.co.uk./articles/-A-431441