On-site thermal diagnostics of cooling sources for air conditioning systems in office buildings
Journal Title: Architecture Civil Engineering Environment - Year 2017, Vol 0, Issue 0
Abstract
The main goal of the Task 4 “Development of thermal diagnostics of buildings” of Strategic Research Project “Integrated System for Reducing Energy Consumption in the Maintenance of Buildings” was to develop new tools for thermal diagnostics of different types of buildings, including development of the rapid method of a cooling sources diagnostics. The paper presents a method for assessing the cooling sources based on on-site measurements. The cooling capacity of the cooling sources and the electric power consumed by the cooling sources were measured in two air-conditioned office buildings. The measurement results were used to calculate the cooling energy generated during the measurement period and the operational Energy Efficiency Ratio EERo of the chillers. Electric energy consumed in the measuring period by the auxiliary equipment of the cooling system, i.e.: coolant pumps and fan coil fans, was estimated. The possibility of significant reduction of the energy consumption for air conditioning in both buildings was indicated.
Authors and Affiliations
M. Hurnik
Architectural features of military architectural structures in Poznań
This paper aims to present architectural and educational features of historic military architectural structures in Poznań. The issues treated herein include the preservation of forts today and the resulting opportunities...
Modeling of energy crops gasification based on experimental data
The paper presents a mathematical model of the selected energy crops gasification. Firstly, the experimental study of the biomass gasification process using fixed-bed reactor was conducted. The highest calorific value wa...
Indoor environment quality evaluation in dwellings: a Polish case study
The indoor environment determines the occupants’ comfort and significantly affects the energy consumed for heating and ventilating the building premises. Therefore, the proper complex thermal diagnostics of existing buil...
On-site thermal diagnostics of cooling sources for air conditioning systems in office buildings
The main goal of the Task 4 “Development of thermal diagnostics of buildings” of Strategic Research Project “Integrated System for Reducing Energy Consumption in the Maintenance of Buildings” was to develop new tools for...
Effect of metakaolin developed from local natural material soorh on workability, compressive strength, ultrasonic pulse velocity and drying shrinkage of concrete
The utilization of pozzolanic materials like metakaolin (MK) in cement mortar and concrete is growing in construction industry all around the world to reduce the CO2 release into the atmosphere and reduce energy consumpt...