Partial Discharge Analysis in Generator Stator Winding Using Artificial Neural Network
Journal Title: روش های هوشمند در صنعت برق - Year 2014, Vol 5, Issue 20
Abstract
This paper analyses the Partial Discharge (PD) on the stator terminals of synchronous generator. This is necessary to collect experimental data for the analysis. First, exploiting the measurement devices, special signals that describe the partial discharges are repeatedly collected. Then, based on the current standards, the collected empirical data are subjected to interpretation. To ease the interpretation process, an Artificial Neural Network is trained and validated. We have used a double layers forward perceptron neural network which is trained by Levenberg–Marquardt algorithm that utilizes least square method as the performance index. As the case study, three gas turbine-generators located in Shahre-Rey power plant (Rey Power Generation Management Company) have been subjected to repeatedly data collection. The mentioned generators are manufactured by Mitsubishi with 85 MW of nominal power. Generally, partial discharge analysis has the following practical implication about the probable defects: lamination of the internal terminal, mobility within the main insulation and discharge into the groove in stator of synchronous generator.
Authors and Affiliations
Seyed Meisam Ezzati, Faramarz Faghihi, Ali Moarefian poor
Investigation and improvement of high step- up converters for pv module applications
sun is of the clean and cheapest sources of energy. Charging slight energy to electricity is carried out by PV modules. Since most electric consumers need Ac input voltage, the PV modules output voltage should be changed...
Upper Bound for Queue length in Regulated Burst Service Scheduling
Quality of Service (QoS) provisioning is very important in next computer/communication networks because of increasing multimedia services. Hence, very investigations are performed in this area. Scheduling algorithms effe...
Adaptive Coordination of Fuse – Recloser in a Distribution System with High PV Penetration
Employment of photovoltaic (PV) distributed Generation in the distribution system, leads to improvement of network voltage profile and power quality. On the other hand, it cause miscoordination between fuses and recloser...
New DC/DC High Step Up Isolated Converter with ZVS
In this paper we presents a soft switch sepic, flyback converter. At first the converter have hard switching in main switch and completely analysis then added auxiliary circuit for soft switching Auxiliary circuit in the...
Performance of Distance Relays in the Presence of Distributed Power Flow Controllers
Recent efforts to increase the power transmission capacity and increase the level of network stability have increased the use of Flexible AC Transmission Systems elements in the power system. The protective system, which...