PHYSICAL MEANING OF THE «REACTIVE POWER» CONCEPT APPLIED TO THREE-PHASE ENERGY SUPPLY SYSTEMS WITH NON-LINEAR LOAD
Journal Title: Електротехніка і Електромеханіка - Year 2015, Vol 0, Issue 6
Abstract
Purpose. The contradictions in the use of the term «reactive power» require justification by clarifying its physical meaning. The aim of the paper is to reveal the physical meaning of the term «reactive power» applied to three-phase three-wire and four-wire energy supply systems. Methodology. We have applied the modern theory of instantaneous active and reactive power, the graphical filling complex branched energy supply system of simplified design scheme, the theory of electrical circuits, computer Matlab-simulation. Results. We have provided answers to six basic questions that reveal the physical meaning and definition of the concept of «reactive power». We have justified the assumptions suggesting a universal calculation formula to determine the relative total power loss in the three-phase energy supply system as the sum of four components caused by: a minimal losses, reactive power, active power pulsations and instantaneous current flow in the neutral wire. Originality. We have developed the definition that reveals the physical meaning of the term «reactive power» for three-phase energy supply systems corresponding to modern theories of instantaneous active and reactive power. Practical value. We have proposed energy efficiency method ideas of energy supply systems with non-linear load based on the additional components of the power losses calculation. The further development of the method will allow to amend the design, selection and operation of the power active filters practices.
Authors and Affiliations
G. G. Zhemerov, D. V. Tugay
EVALUATION OF POWER TRANSFORMER INSULATION RESIDUAL LIFE BASED ON ITS INDIVIDUAL LIFE CYCLE CHARACTERISTICS
Analysis reveals that all phases of a power transformer life cycle have a significant effect on the isolation resource. The paper introduces a technique for evaluating residual life of power transformer insulation via si...
APPLICATION OF VYSHNEGRADKY'S DIAGRAMS FOR TRANSIENT ANALYSIS IN ELECTRIC DISCHARGE INSTALLATIONS WITH STOCHASTIC LOAD
Purpose. To analyze the transient processes in the discharge circuit of reservoir capacitor of electric discharge installations at a change in the circuit configuration during the discharge as well as to determine the ap...
INVESTIGATION OF HIGH-CURRENT INTERRUPTING CONTACTS WORKING SURFACES MECHANICAL INTERACTION NATURE
Introduction. The nature of the interaction of high-working surfaces of the electrical contact uniquely affects their performance. By the failure of the contacts in the main drive processes resulting from complex destruc...
CALCULATION OF MAGNETIC FIELD OF THREE-PHASE CABLE LINES WITH TWO-POINT BONDED CABLE SHIELDS COVERED BY FERROMAGNETIC CORES
In this paper we obtain compact expressions for the magnetic field shielding factor of a high-voltage three-phase cable line consisting of single-core cables with two-point bonded cable shields and ferromagnetic cores in...
CONTROL SYSTEM FOR MULTILEVEL INVERTOR OF SOLAR POWER STATION
Purpose. The development of control law for network multilevel invertor of solar power station and design device for control law realization. Methodology. At synthesis of control law theory of automatic control, power ne...