Predictors of Mechanical Failure Rate in Reduction of Intertrochanteric Fracture of the Femur Using Proximal Femoral Nail with Helical Blade

Journal Title: Journal of Orthopedics & Rheumatology - Year 2018, Vol 5, Issue 1

Abstract

Background: The optimal implant for reducing intertrochanteric fracture is unknown. Several bone-related, implant-related and radiological variables seem to play a role in predicting the rate of intraoperative and postoperative mechanical failure. The objective of this study was to evaluate the rate and predictors of mechanical failure and its relationship with quality of reduction through assessing certain radiological parameters. Materials and methods: A retrospective study reviewed patients with stable (AO/OTA Type 3.1A1) and unstable (AO/OTA Type 3.1A2 and A3) intertrochanteric femur fracture who were treated with proximal femoral nail with helical blades (PFNA) between 2011 and 2017. Exclusion criteria were patients with pathologic fractures. Followup was undertaken at 1 day, 4-6 weeks, and 3 months postoperatively by reviewing radiographs and medical charts. The primary outcome was the rate of mechanical failure. Radiologic parameters of Tip apex distance (TAD), neck shaft angle and displacements were evaluated as indicators of reduction quality. All these were compared to each other and baseline patient characteristics to identify any association. Results: We found 69 patients who underwent PFNA procedure. There was no case of intraoperative or postoperative mechanical failure or non-orthopedic complication. The postoperative radiological outcomes revealed variable quality of reduction with: mean TAD of 26.07±3.69° (bimodal), mean neck shaft angle of 133±5.6° (range: 116-140°), 35% of patients having lesser trochanter displacement, 28% having displaced femoral shaft. There was no statistical significant relation between any of the radiological outcomes and patient characteristics except between neck shaft angle and osteoporosis (p=0.03). Conclusion: The radiological outcomes are independent of the patient’s characteristics except for Neck Shaft Angle and Osteoporosis. Absence of mechanical failure despite the variability in reduction quality (optimal/suboptimal) might be explained by the decent implant design. Further studies are needed to confirm that PFNA implant design is the major preventer of mechanical failure.

Authors and Affiliations

Ahmad Salaheddine Naja

Keywords

Related Articles

Lumbar Epidural Injections: Review of Efficacy and Discussion of Practice Options

Background: In the United States, low back pain remains a common problem and a number one reason to see a physician in the outpatient setting. Etiology is complex and likely multifactorial and includes; degenerative disc...

Distal Radioulnar Joint Synovial Osteochondromatosis - A Case Report and Review of Literature

Synovial chondromatosis is a rare benign clinical condition, with a rare location in the wrist. This study presents a case of synovial chondromatosis in the distal radioulnar joint (DRUJ) treated successfully with surgic...

Musculoskeletal Hospital Admission and Surgical Procedure Rates among Patients Treated for Rheumatoid Arthritis in the Netherlands 1999-2012

Objectives: To assess trends in hospitalizations among patients receiving rheumatoid arthritis (RA)-treatment in a 14-year period compared with population references. Methods: Patients treated for RA with any disease-mo...

Adipofascial Posterior Interosseous Reverse Flap for Soft Tissue Loss on Dorsal Aspect of the Hand

Soft tissue defects of hand should be carefully evaluated to determine the most appropriate alternative for coverage. Thirteen patients with soft tissue loss on dorsum of the hand were managed by reversed septo fascial P...

Yoga as a treatment for chronic low back pain: A systematic review of the literature

Objectives: Chronic low back pain (CLBP) affects millions of people worldwide, and appears to be increasing in prevalence. It is associated not only with pain, but also with increased disability, psychological symptoms,...

Download PDF file
  • EP ID EP488194
  • DOI 10.13188/2334-2846.1000039
  • Views 97
  • Downloads 0

How To Cite

Ahmad Salaheddine Naja (2018). Predictors of Mechanical Failure Rate in Reduction of Intertrochanteric Fracture of the Femur Using Proximal Femoral Nail with Helical Blade. Journal of Orthopedics & Rheumatology, 5(1), 1-5. https://europub.co.uk./articles/-A-488194