Pushover Analysis for Multistorey RC SMRF and OMRF

Abstract

for a long time. The poor performance of Ordinary Moment Resisting Frame (OMRF) in past earthquakes suggested special design and detailing to warrant a ductile behavior in seismic zones of high earthquake (zone III, IV & V). Thus when a large earthquake occurs, Special Moment Resisting Frame (SMRF) which is specially detailed with a response reduction factor, R = 5 is expected to have superior ductility. The response reduction factor of 5 in SMRF reduces the design base shear and in such a case these building rely greatly on their ductile performance. To ensure ductile performance, this type of frames shall be detailed in a special manner recommended by IS 1392. Special proportioning and detailing requirement results in frame capable of resisting strong earthquake shaking without significant damage. These moment resisting frame are called as “Special Moment Resisting frames”. In this study, the buildings are designed both way as SMRF and OMRF, and their performance is compared. For this the buildings are modeled and pushover analysis is performed in SAP2000.

Authors and Affiliations

Saudamini Jambhulkar, Prof L G Kalurkar

Keywords

Related Articles

Application of soft computing techniques in dental Image Segmentation

Image segmentation is a very important and pre-processing step in image analysis. The conventional multilevel thresholding methods are efficient for bi-level thresholding because of its simplicity, robustness, less conve...

Modified Median Filter for Removal of High Density Salt and Pepper Noise

In the Transmission of pictures over channels, Images are debased by salt and pepper commotion, because of defective correspondences. Salt and Pepper clamor is likewise alluded to as Impulse commotion. The target of sift...

A Rational Study on Strategies Adopted by the Manufacturing Engineering Firms - in Order to Protect their Core Activities while Outsourcing Engineering Design and Product Development – A Paradigm Shift.

Rapidly changing and increasingly complex business forces are bringing dynamic shifts in management practices in any type of organisation, whether it may be a production sector or service sector. The advancing of technol...

Moringa Seed, Residual Coffee Powder, and Banana Peel as Biosorbents for Uranium Removal from Acid Mine Drainage

The uranium mining deserves attention with regard to environmental impacts and water pollution in Brazil. The research objective was to enable the use of biomass as cheap and available adsorbents for uranium removal from...

Heat Transfer Enhancement in a Smart Phone

Smart phones are posed with heat transfer problems due to the space and weight limitation and also due to ever increasing processer speed. In this work, heat transfer in a Xiaomi Mi4i smart phone model has been studied u...

Download PDF file
  • EP ID EP392102
  • DOI -
  • Views 89
  • Downloads 0

How To Cite

Saudamini Jambhulkar, Prof L G Kalurkar (2017). Pushover Analysis for Multistorey RC SMRF and OMRF. International Journal of engineering Research and Applications, 7(9), 5-9. https://europub.co.uk./articles/-A-392102