Resonant Conditions in a Node with an SVC Compensator

Journal Title: Acta Energetica - Year 2016, Vol 28, Issue 3

Abstract

The primary purpose of installing static shunt compensators in power grids is to improve the voltage conditions. Additional reactive power sources increase the system’s voltage stability and enable faster system recovery after a voltage failure. This paper presents the impact of an SVC device’s structure and settings on impedance change in the supply system, and hence on the frequencies at which resonance phenomena can develop.

Authors and Affiliations

Robert Kowalak

Keywords

Related Articles

Evaluation of The Operation and Improvement of the Stability of the Factory Power Network, Taking into Account the Uncertainty of the Network Model Parameters

There was analysed the operation of a factory power network working in island mode and cooperating with the Polish National Power System (PNPS) in selected transient states. It was assumed that two generating units: one...

Comparison of Transmission Capacities of Two Regulation Systems: Lateral and in-phase Control Transformers

This paper presents a comparison of regulation capabilities of lateral and in-phase control transformers in a selected node of a power system. Their regulation capabilities are presented, as well as cross-system exchange...

Effect of dE-NOx techniques employed in thermal power plants on fly ash properties

Coal fly ash, a by-product of coal combustion in thermal power plants, is one of the most complex and abundant of anthropogenic materials. For several years, fly ash has predominantly been used as a substitute for materi...

Simplified Distribution Grid Modelling for Connection Analyses

This paper considers the modelling of medium and low voltage grids for the purpose of connection studies by distribution grid operators. Possible simplifications in grid modelling are discussed, which are acceptable from...

Problems of Selecting Protection for Shunt Reactors Working in Extra-High Voltage Grids

This paper presents difficulties encountered when designing protection devices for shunt reactors connected directly to extra-high voltage grids. Using the example of the 400 kV Ełk Bis substation, it has been demonstrat...