Simulation of 3 Phase, 24 Pulse GTO Converter for Flow Control of Transmission System
Journal Title: International Journal of Trend in Scientific Research and Development - Year 2019, Vol 3, Issue 5
Abstract
Gate Turn off GTO thyristor based power control controller for flow control of transmission system is used to regulate voltage and reactive power improment. GTO thyristor switching devices with high power handling capability and the advancement of the other type of power semiconductor devices such as IGBTs, MOSFETs, Ideal switch and so on have led to the development of fast controllable reactive power source utilizing new electronic switching and converter technology. Nowadays, the development of a large capacity Gate Turn off thyristor has made it possible to manufacture self commutated converter employing GTO thyristor for power applications. At present, most of the research on GTO thyristor has focused on their use in power electronic systems at high switching frequencies. GTO thyristor enable the design of the solid state shunt equipment based upon switching technology. The improved rating of GTOs made possible the use of voltage sourced converter VSC in power system applications. In this paper, GTO based voltage source converter VSC is used in high power Flexible AC Transmission Systems FACTS which are used to control power flow on transmission grids. It can be used to build a model of shunt or series static compensator STATCOM or SSSC or, using two such converters, a combination of shunt and series devices known as Unified Power Flow Controller UPFC . This paper has shown a basic application of MATLAB SimPowerSystems programming for 24 pulse GTO converter STATCOM. Zin Wah Aung | Aye Myo Thant | Hnin Yu Lwin "Simulation of 3-Phase, 24 Pulse GTO Converter for Flow Control of Transmission System" Published in International Journal of Trend in Scientific Research and Development (ijtsrd), ISSN: 2456-6470, Volume-3 | Issue-5 , August 2019, URL: https://www.ijtsrd.com/papers/ijtsrd27887.pdfPaper URL: https://www.ijtsrd.com/engineering/electrical-engineering/27887/simulation-of-3-phase-24-pulse-gto-converter-for-flow-control-of-transmission-system/zin-wah-aung
Impact of Shading, Soiling and Temperature on Solar Photovoltaic System
The main objective of this research paper is to study the effect due to shading, temperature, dust accumulation, snow, birddropping. The power output of the solar panels dependent upon the amount of sun radiation which r...
Bagasse Level Monitoring System
As industrial revolution approaching towards automa-tion they need to upgrade their manufacturing process. We were visited to Siddhanath sugar factory, in boiler section, we found a problem with bagasse silo that it does...
Impact Assessment of Fluorosis Mitigation Project, A Case Stydy of Nagour
The present study has been undertaken to evaluate the impact assessment of the fluorosis mitigation project in the Nagaur district (Raj). Nagour is a centrally located district of Rajasthan state of India which is a part...
Problems of Formation of Cartographic Competence at the Modern Stage of Higher Education Development
This scientific article describes the results of research on the transition from the traditional knowledge paradigm of education to the level of personal development for the modern stage of development of higher educatio...
Customer Service Evaluation Applied to Pedagogy Degree
The objective of the present study is to evaluate the customer service applied to the pedagogy degree in its night shift. To carry out this research, a population study was applied and a representative sample was calcula...