Structurally technical the aspects of measuring of concentration of easy aeroions are In-process considered the method of the opened collector

Abstract

Вasic methods of measuring of concentration of easy aeroions, the features of their use, advantage, and failings are certain. It is suggested to use the method of the opened collector for measuring the concentration of easy aeroions. Technical and construction features are described realization of this method, which allow to conduct measuring of concentration of easy aeroions of air space of environment regardless of their state, closeness and speed of moving. A device, which will realize the method of the opened collector, which provides high exactness, sensitiveness and measuring speed, and also allows to conduct measuring in the concrete point of space, is described, to look after and fix intensity of concentration of electric charges of aeroions. Experimental verification of capacity of this method is conducted.

Authors and Affiliations

O. Korenivska

Keywords

Related Articles

Impedance models of double well structures

Introduction. In this paper the impedance models double well structures (DWS) which is based on δ-inhomogeneities and rectangular potential are developed. The models of double well potential which is based on δ-functions...

Wideband bioimpedance meter with the adaptive selection of frequency grid

Introduction. For the diagnosis of functional state and structure of biological objects with weakly expressed irregularities it is important quickly and accurately to determine the amplitude- and phase-frequency characte...

The sensitivity in Electrical Impedance Tomography

Introduction. The concept of sensitivity in Electrical Impedance Tomography is introduced (first – fourth type). The experimental researches measuring the voltages on the phantom outline are conducted on the created layo...

Radioholographic motion sensor

The new principle of constructing of the motion sensor which  fixes a repositioning of objects in considered radiation zone, is examined. It is offered to watch a repositioning of objects behind change of a phase of the...

Methodology for determining the reliability of fault-tolerant hardware-software radioelectronic systems

Introduction. The majority of radioelectronic systems are hardware-software systems. Their reliability is defined as the reliability of hardware and software. Methods for estimating software allow to predict reliability...

Download PDF file
  • EP ID EP309214
  • DOI 10.20535/RADAP.2012.49.142-150
  • Views 52
  • Downloads 0

How To Cite

O. Korenivska (2012). Structurally technical the aspects of measuring of concentration of easy aeroions are In-process considered the method of the opened collector. Вісник НТУУ КПІ. Серія Радіотехніка, Радіоапаратобудування, 0(49), 142-150. https://europub.co.uk./articles/-A-309214