Suitability Assessment of Two Types of Heat Exchangers for High Temperature, Naturally Circulating Helium Cooling Loop

Journal Title: Strojnicky casopis - Journal of Mechanical Engineering - Year 2019, Vol 69, Issue 1

Abstract

The paper presents a comparison of the process properties of two types of the heat exchangers designed for the heat removal from a high temperature helium cooling loop with steady natural circulation of helium. The first considered heat exchanger is a shell and tube heat exchanger with U-tubes and the other one is a helical coil heat exchanger. Using the thermal and hydrodynamic process calculations, the thermal performance of the two alternative heat exchangers are determined, as well as the pressure drops of flowing fluids in their workspaces. The calculations have been done for several defined operating conditions of two considered types of heat exchangers. The operating conditions of heat exchangers correspond to the certain helium flow rates.

Authors and Affiliations

František Dzianik, Štefan Gužela and Eva Puškášová

Keywords

Related Articles

Natural Fibers and Biopolymers Characterization: A Future Potential Composite Material

Now days, green composite materials are now gaining popularity for the various industrial applications. It is a combination of naturally occurring reinforcement like jute, sisal, flax, hemp, and kenaf; and matrix mater...

All-Pass Filters in the Systems of Active Vibration Control of Weakly-Damped Systems

The problem of active vibration control of weakly damped mechanical structures is potentially unstable modes of vibrations due to the positive feedback for some vibration modes. The paper will discuss the change of pos...

Neural Networks - A Way to Increase the Fuel Efficiency of Vehicles

This paper deals with the possibility of creating a vehicle model using a hierarchy of neural networks. Based on this model, it is possible to build an optimization cycle that looks for parameters which are influencing...

Influence of Bypass on Thermo-Hydraulics of VVER 440 Fuel Assembly

The paper deals with CFD modelling and simulation of coolant flow within the nuclear reactor VVER 440 fuel assembly. The influence of coolant flow in bypass on the temperature distribution at the outlet of the fuel ass...

ELASTOSTATIC ANALYSIS OF THE SPATIAL FGM STRUCTURES

In this contribution, results of elastostatic analysis of spatial composite beam structmes are presented using ow- new beam finite element of double symmetric cross-section made of a Ftmctionally Graded Material (FGM)....