The Annual Effective Dose for Some Food Crops Samples Using Alpha Track Detector
Journal Title: JOURNAL OF ADVANCES IN PHYSICS - Year 2017, Vol 13, Issue 7
Abstract
Radon gas arrives the indoors from different sources and very important in human life because it is harmful on the human population. Radon concentrations were measured in some crops samples from the local market by Suez government, Egypt, using alpha track detector from the type of CR-39. The values of the annual effective dose varied from 1.94 - 1.21mSvy-1. The obtained results indicate that the values of annual effective dose lower than the recommended limit of ICRP. We conclude that there is no health hazard due to radon gas, when used in eating of the food crops samples in this study. This work will help to provide an important database about the radiation hazard from food crops, which used in our houses.
Authors and Affiliations
Hesham A. Yousef
Axiomatic Local Metric Derivatives for Low-Level Fractionality with Mittag-Leffler Eigenfunctions
In this contribution, we build up an axiomatic local metric derivative that exhibits Mittag-Leffler function as an eigenfunction and is valid for low-level fractionality, whenever the order parameter is close to 1. This...
The The Anisotropy of Electron Scattering in Uniaxially Deformed N-Si Single Crystals with Radiation Defects
The tensoresistance at the uniaxial pressure along the crystallographic direction [100] for n-Si single crystals, which were irradiated by the different doses of gamma quants was investigated. On the basis of the theory...
A perpetuum mobile of second kind is possible
 Great and important discoveries befall there seldom, but this one is just such a discovery. The discovery is in physics which disproves the validness of the second law of thermodynamics and several others up to now con...
Few possible models for 19.9%efficient
: Device modeling and simulation studies of a CIGS thin film solar cell have been carried out using SCAPS 2902. A variety of graded band gap structures of efficiency around 19.9% are examined. The study shows that materi...
The measurement of photoneutron dose around an 18 MV Varian linear accelerator by TLD600 and TLD700 dosimeters inside the polyethylene sphere of neutron probe LB 6411
Bremsstrahlung X-rays from high-energy linear accelerators (Linacs) produce neutrons as a result ofphotonuclear reactions mainly with the different materials constituting the accelerator head. The neutronsproduced during...