The clinical applications of body weight and endotracheal tube size prediction formulas in pediatric patients

Abstract

There are various formulas and algorithms for the prediction of body weight and appropriate ETT size, in pediatric patients. Body Weight estimation is of paramount importance in pediatrics, especially in emergencies. Predicting the appropriate size of the endotracheal tube saves time, money and reduces complications. The goal of this study was to evaluate the validity of two commonly used formulas for predicting the body weight and the size of the appropriate endotracheal tube, both based on age.353 consecutive pediatric surgical patients aged 2 to 12 years, who required general anesthesia and oral endotracheal intubation were included in this study. Patients were stratified according to their age in two groups: group 2-5 (79 children, 2 to 5 years) and group 6-12 (274 children, 6 to 12 years). At the end of surgery an anesthesiologist, who was not involved in the perioperative treatment, recorded the demographic data and also the size and type of the endotracheal tube used. The prediction of Body Weight (BW) was made according to the following formula: 2-5 y.o.: Weight (kg) = (2 x age in years) + 8 and 6-12 y.o.: Weight (kg) = (3 x age in years) + 7. The formula for calculating the size (size= internal diameter=I.D.) of the endotracheal tube (ETT) was: I.D. for cuffed ETT (mm) = (age / 4) + 3.5 and I.D. for uncuffed ETT (mm) = (age / 4) + 4. For all statistical tests p value <0.05 was considered as statistically significant. In all patients as sum and in both age groups, the predicted body weight was significantly (p<0.05) lower than the actual (measured) weight. In group 2-5y.o, 74.7% of patients received cuffed ETT In group 6-12y.o. 100% of patients received cuffed ETT. In group 2-5 y.o, all patients showed a significantly (p<0.05) lower predicted internal diameter of the ETT, either cuffed or uncuffed, compared to ETT ultimately used. In group 6 -12y.o, there was no statistically significant difference between the predicted and the actually used ETT size. The prediction of body weight in children, by the use of the particular formula, led to underestimation. In children aged 2 to 5 years, the application of the inner diameter calculation of the ETT formula also underestimated the appropriate ETT size. It seems that the traditional age-based formulas often fail to predict the correct ETT size in smaller children which probably does not seem to apply to older children.

Authors and Affiliations

PInelopi Papagiannopoulou, Vajia Ntritsou, Kalliopi Pistofidou, Athina Mademli, Dimitrios Stefanovitis, Andreas Isaakidis, Christos Costoglou, Chrysanthi Zachariadou

Keywords

Related Articles

ANESTHESIOLOGY CONSIDERATIONS DURING MAXILLOFACIAL SURGERY IN A CHILD WITH NOONAN’S SYNDROME: A CASE REPORT.

Noonan syndrome (NS) is an autosomal dominant disorder characterized by anatomic and pathophysiologic abnormalities.Anesthetic management in these cases has many challenges regarding airway management and cardiovascular...

Eosinophilia: An early marker of adrenal insufficiency in critically ill patients with septic shock?

Adequate adrenocortical function is essential to survive critical illness. The goal of this study was to determine whether eosinophilia could serve as a useful and early marker of adrenal insufficiency in critically ill...

Pacemaker syndrome during temporary epicardiac pacing, after coronary artery bypass grafting: case report and review of the literature

The deficiency of the natural heart pacemaker, the conduction disturbances and the appearance of arrhythmias are common complications after cardiac surgery. Placement of epicardiac electrodes (ventricular, atrial, or bot...

Perioperative Haemostaticmonitoring: older vs. newer concepts and techniques

Clinical management of acute severe bleeding in the perioperative setting is one of the major challenges for an anesthetic team. The dynamic nature of bleeding calls for rapid diagnosis and immediate interventions. Traum...

Ventricularization of Right Atrial Pressure Waveform

Central venous pressure (CVP) measurement along with invasive arterial pressure measurement are the two most widely used monitoring parameters in the Intensive Care Unit (ICU) and in the operating room (OR).In contrast w...

Download PDF file
  • EP ID EP422740
  • DOI -
  • Views 113
  • Downloads 0

How To Cite

PInelopi Papagiannopoulou, Vajia Ntritsou, Kalliopi Pistofidou, Athina Mademli, Dimitrios Stefanovitis, Andreas Isaakidis, Christos Costoglou, Chrysanthi Zachariadou (2017). The clinical applications of body weight and endotracheal tube size prediction formulas in pediatric patients. Ελληνικό ηλεκτρονικό Περιοδικό Περιεγχειρητικής Ιατρικής, 16(0), 26-36. https://europub.co.uk./articles/-A-422740