The Influence of Number of Signal Average Variation to the Scan Time and Anatomic Information of Lumbar MRI on Sagittal Slice with Stir Sequence
Journal Title: Journal of Medical Science And clinical Research - Year 2017, Vol 5, Issue 6
Abstract
Background: The number of signal averages (NSA) parameters is one of the parameters that can affect the quality of the MRI image making the selection of accurate parameters is necessary to produce an optimal image produced and a short imaging time. Objectives: The purpose of this study was to determine the effect of variations in the value of the NSA to scan time and get a lumbar MRI anatomical image on sagittal STIR sequences and NSA that generate value anatomic information with an optimal scan time on lumbar MRI sagittal STIR sequences. Method: This research is a quantitative research experiment conducted with a 1.5 Tesla MRI at the Kasih Ibu Hospitals Denpasar. Data are in the form of 50 image sagittal STIR sequences MRI lumbar of the 10 volunteers with five NSA variations (1, 2, 3, 4 and 5). The assessment is performed by 3 people regarding information generated imagery and data were analyzed by using Friedman test. Result: The results showed that there was the influence of variations in the value of the NSA to scan time and a lumbar MRI anatomical image slices sagittal with STIR sequences with a significance level of p value <0.05. Based on an assessment of the respondents, the value of the NSA which produce good anatomical information at the lumbar spine MRI sagittal slice with STIR sequences is NSA 5. And the NSA optimal value is based on the standard of NSA 2 relative value of SNR and scan time. Conclusion: there was the influence of variations in the value of the NSA to scan time and get a lumbar MRI anatomical image slices sagittal with STIR sequences with a significance level of p value <0.05. The value of the NSA which produced good anatomical information at the lumbar spine MRI sagittal slice with STIR sequences is NSA 5. And the NSA optimal value is based on the standard of NSA 2 relative value of SNR and scan time
Authors and Affiliations
Andi Tenri Citra Latifa
Ramosetron vs Ramosetron with Dexmedetomidine for Prevention of Postoperative Nausea Vomiting and Shivering after Gynaecological Laparoscopic Surgery: A Comparative Study
Background: Postoperative nausea and vomiting (PONV) and postanesthetic shivering (PAS) are common postoperative patient complaints that can be very distressing and may result in adverse physical outcomes. A combination...
A Prospective Study of Incidence and Outcome of Acute Kidney Injury Patients Admitted in Medical ICU of Tertiary Care Center
Background: Acute Kidney Injury (AKI) is characterized by a rapid decline in glomerular filtration rate over hours to days. Before 2004 there more than 35 definitions in medical literature for AKI, so a wide range of inc...
Detection of an asymptomatic non-palpable non-lymphomatous CD8+ splenic hamartoma
Present case report relates to the incidental finding of a splenic hamartoma during a medical check-up. Later, splenectomy was done. Tumor measured 3.5×3×3 cms. Microscopic examination of tumor showed unencapsulated diso...
Secondary Hemophagocytic Lymphohistiocytosis: Morphological Findings of Spleen and Bone Marrow with Discussion of Management of an Atypical Case
Hemophagocytic lymphohistiocytosis is syndrome due to abnormal and exaggerated immune response to infectious and non-infectious agents. The most common presentation is fever with palpable splenomegaly and pancytopenia. I...
An Incidental Finding of Enormous Number of Multiple Gall Stones in a Tertiary Setup in Western India
In this case report we state the occurrence of 800 gall stone found in a single patient undergoing elective cholecystectomy. The largest number of the gallstone found in a single patient is 11970.the occurrence of gallst...