Wear of the Implant Connection with Zirconia and Titanium Abutments

Journal Title: Open Access Journal of Dental Sciences - Year 2016, Vol 1, Issue 1

Abstract

Background: Classify and quantify the wear of the implant and abutment interface simulating a loose screw situation. Methods: Nine external connection titanium implants were split into 4 groups: Group A (no hexagon titanium abutment), Group B Titanium abutment (with hexagon) (n=3), Group C Zirconia abutment with hexagon (n=3) and Group D mix abutments (n=2). All components were individually weighted and the rotational freedom for each pair was access before and after testing. The specimens were tested an Instron 8874 fitted with a dynamic load cell with a torque capacity of 100Nm and a precision of 0.5% from 1% of the full scale. They were loaded with a sinusoidal rotational angle that was different for each group (A= 6º, B= 3.3º, C= 0.835º, D=6.6 º), 4 Hz, for 250.000 cycles. After testing all components were photographed with a SEM. Spearman’s correlation analysis was made. Results: Regardless of angle and materials the rotational freedom increased in all groups. Volume loss with zirconia abutment was more than double than with a titanium abutment. Conclusion: The loose screw in implant prosthesis may lead to the wear of the hexagon on both components. This wear is sufficient to compromise the connection beyond repair.

Authors and Affiliations

José AR

Keywords

Related Articles

Teledentistry–An Alternative Dental Service

The aim of this editorial is to recommend an alternative method to deliver dental services by using digital technology which is called ‘Teledentistry’. It is not a specialty. There area lot of innovative technologies evo...

Antibiotics in Dentistry-Double-Edged Sword

Since the advent of Antibiotics, the outlook of the Physician about the power drugs can have on diseases has changed. Antibiotics in the recent years have become one of the most frequently used as well as misused drugs....

A Case of Denture Injury Tumor

A 66 year old, male patient walked into the outpatient department with a complaint of loose teeth set in the lower front region, since 5 months and desired replacement of the teeth set. The lower incisors were mobile and...

Teledentistry – An Alternative Dental Service

The aim of this editorial is to recommend an alternative method to deliver dental services by using digital technology which is called ‘Teledentistry’. It is not a specialty. There area lot of innovative technologies evo...

The Proper Toothpaste for Children

Oral hygiene is important in childhood and adolescence. For this reason, the need for training and the use of proper toothpaste for children is essential for parents. This article is about how to use toothpaste for child...

Download PDF file
  • EP ID EP285101
  • DOI -
  • Views 106
  • Downloads 0

How To Cite

José AR (2016). Wear of the Implant Connection with Zirconia and Titanium Abutments. Open Access Journal of Dental Sciences, 1(1), 1-9. https://europub.co.uk./articles/-A-285101