Damages to stent stabilized left ventricular pacemaker electrodes during simulated lead extraction 

Journal Title: Frattura ed Integrità Strutturale - Year 2011, Vol 5, Issue 16

Abstract

During biventricular pacemaker implantation stents can be applied for coronary sinus lead stabilization to prevent lead dislocations. A lot of issues have been raised in connection with the use of the stent. In some cases the implanted left ventricular lead must be explanted. It is crucial to avoid any injury to the heart when the electrode is removed. Another very important question concerns the type of injuries the electrode may cause during the removal process. An extraction model has been prepared using a special curve and a polymer tube. After the pacemaker leads were extracted, various microscopic examinations were executed. The findings may to make such intervention methods more successful, helping to better stabilize the electrode and to keep injuries during interventions to a minimum. 

Authors and Affiliations

Romola Laczkò, Tibor Balzs, Eszter Bognàr, Jànos Ginsztler

Keywords

Related Articles

 Energy dissipation mechanism and damage model of marble failure under two stress paths

 Marble conventional triaxial loading and unloading failure testing research is carried out to analyze the elastic strain energy and dissipated strain energy evolutionary characteristics of the marble deformation...

Verifica a fatica dei giunti saldati sulla base di misure di deformazione locale 

Lo studio della resistenza a fatica delle giunzioni saldate rappresenta un campo di prova molto interessante dal punto di vista scientifico, con ricadute pratiche altrettanto importanti. Si tratta in generale di fornire...

 Influence of different sizes of concrete and roller compacted concrete on double-K fracture parameters

 Affected by physical properties of various components, characteristics and stress states of junction surface and other multiple factors, concrete, as a kind of multi-phase composite material, has complicated ...

 Characterisation of crack tip fields under non-uniform fatigue loading

The paper analyses previously reported work, which uses digital image correlation to measure fatigue crack closure. As well as determining crack opening loads, the information on crack shape may be used to estimate the s...

 Fracture morphology and its evolution  A review on crack path stability and brittle fracture along butt-weld

 Considerations are made for the fracture morphology and its evolution in relation to the brittle fracture along butt-weld, where crack path stability may play important roles in various aspects. Analyses of a&nbsp...

Download PDF file
  • EP ID EP113836
  • DOI 10.3221/IGF-ESIS.16.03
  • Views 77
  • Downloads 0

How To Cite

Romola Laczkò, Tibor Balzs, Eszter Bognàr, Jànos Ginsztler (2011). Damages to stent stabilized left ventricular pacemaker electrodes during simulated lead extraction . Frattura ed Integrità Strutturale, 5(16), 28-33. https://europub.co.uk./articles/-A-113836