Surgical efficacy after two different surgical methods on visual field and RNFL thickness in patients with glaucoma

Journal Title: Guoji Yanke Zazhi - Year 2018, Vol 18, Issue 10

Abstract

AIM:To compare the effects after two different surgical methods on visual field and retinal nerve fiber layer(RNFL)thickness in patients with glaucoma. <p>METHODS: Clinical data of 69 cases patients(82 eyes )with glaucoma between December 2015 to May 2017 in our hospital for anti-glaucoma surgery were collected. According to operation method, they were divided into EP group(EX-PRESS glaucoma shunt implantation)and XQ group(trabeculectomy). Intraocular pressure, anterior chamber depth(ACD), anterior chamber capacity(ACV), anterior chamber angle width(ACA), optical pupil diameter(PD), visual acuity, visual sensitivity index mean defect(MD), visual correction pattern standard deviation(CPSD), mean sensitivity(MS)and retinal nerve fiber layer thickness(RNFLT)were observed in the preoperative, postoperative 1mo and postoperative 3mo, and the postoperative complications were compared. <p>RESULTS: Hospitalization time of 3.08±0.42d in the EP group was significantly lower than 4.53±1.28d in the XQ group(<i>t</i>=6.124, <i>P</i><0.05). The visual recovery time of 3.26±0.30d in the EP group was significantly lower than 4.96±1.36d in the XQ group(<i>t</i>=6.920, <i>P</i><0.05). The ACA, ACD and ACV after surgery of two groups were significantly higher than those before operation, and the PD after surgery was lower than before operation, and the differences were not statistically significant between two groups after surgery(<i>P</i>>0.05).The postoperative RNFLT, MD and CPSD were all decreased in both groups(<i>P</i><0.05), and postoperative MS increased(<i>P</i><0.05); compared with XQ group, the postoperative CPSD after surgery in EP group was significantly reduced(<i>P</i><0.05).The total incidence of postoperative complications of EP group was 38%, which was significantly lower than 70% in XQ group, the difference was statistically significant(<i>χ</i><sup>2</sup>=8.094, <i>P</i>=0.004). <p>CONCLUSION: Compared with trabeculectomy, EX-PRESS glaucoma shunt implantation is more effective to slow the progress of vision, and it is more conducive to recovery of the patient's vision after surgery with higher security. The improvement of the thickness of the retinal nerve fibers after EX-PRESS glaucoma shunt implantation is consistent with trabeculectomy.

Authors and Affiliations

Yun-Yun Zhu

Keywords

Related Articles

Ranibizumab with photodynamic therapy in the treatment of wAMD

AIM: To investigate the clinical effect of Ranibizumab combined with photodynamic therapy(PDT)for wet type age-related macular degeneration(wAMD)and the effect on the serum neovascularization factors. <p>METHODS: Totally...

Research progress on the pathogenesis of microvascular neuropathy in diabetic retinopathy

Diabetic retinopathy is one of the common and serious microvascular complications of diabetes. In foreign countries, DR is the leading cause of blindness in the working age group(20-64 years). In China, the incidence of...

Correlation between macular morphology and visual acuity and visual distortion in acute central serous chorioretinopathy

AIM: To investigate the correlation between macular morphology and visual acuity and visual deformation in acute central serous chorioretinopathy(CSC). <p>METHODS: A cross-sectional clinical case-control study was conduc...

Effects of fundus laser combined with anti-VEGF therapy on serum levels of NOS, VEGF and IL-6 in patients with diabetic macular edema

AIM: To investigate the effects of fundus laser combined with anti-vascular endothelial growth factor(VEGF)therapy on serum levels of NOS, VEGF and IL-6 in patients with diabetic macular edema. <p>METHODS: From May 2015...

Corneal densitometry and its correlation with anterior and posterior elevation in keratoconus

AIM: To evaluate the corneal densitometry in treatment-naive patients with keratoconus and its relevance with anterior and posterior corneal elevation.<p>METHODS: Keratoconic corneas were examined using the Pentacam. Cor...

Download PDF file
  • EP ID EP547646
  • DOI 10.3980/j.issn.1672-5123.2018.10.22
  • Views 128
  • Downloads 0

How To Cite

Yun-Yun Zhu (2018). Surgical efficacy after two different surgical methods on visual field and RNFL thickness in patients with glaucoma. Guoji Yanke Zazhi, 18(10), -. https://europub.co.uk./articles/-A-547646